AC power

Read Safety information on page 4 before connecting the
fixture to AC mains power.
Warning! The mains power input cable supplied with the fixture
is rated 6 A and can supply only one fixture with mains power.
Do not connect any device to the fixture's MAINS OUT power
throughput socket when using this input cable. If you want to
connect other fixtures to the MAINS OUT socket, see 'Linking
fixtures to power in a chain' on page 11.
For protection from electric shock, the fixture must be grounded
(earthed). The power distribution circuit must be equipped with a
fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixture can easily be disconnected from
power.
Do not insert or remove live Neutrik PowerCon connectors to apply or cut
power, as this may cause arcing at the terminals that will damage the
connectors.
Do not use an external dimming system to supply power to the fixture, as this
may cause damage to the fixture that is not covered by the product warranty.
Power input and throughput cables must be rated 16 A minimum, have three
conductors 1.5 mm² (16 AWG) minimum conductor size and an outer cable
diameter of 5 - 15 mm (0.2 - 0.6 in.). The cables must be hard usage type
(SJT or equivalent) and heat-resistant to 90° C (194° F) minimum. In the EU
the cables must be HAR approved or equivalent.
The fixture can be hard-wired to a building electrical installation if you want to
install it permanently, or a power plug (not supplied) that is suitable for the
local power outlets can be installed on the supplied power cable.
If you install a power plug on the power cable, follow the plug manufacturer's
instructions and connect the wires in the power cable as shown in this table:
US system
EU system
The fixture has an auto-ranging power supply that accepts AC mains power at
100-240 V at 50/60 Hz. Do not apply AC mains power at any other voltage or
10
Earth, Ground or
Green
Yellow/green
RUSH PAR 2 RGBW Zoom User Manual
Neutral or N
White
Blue
Live or L
Black
Brown