TITLED VIDEO OUTPUT MODULE

RESTORING FACTORY DEFAULTS

Rev 1.0
With the output module out of the chassis and disconnected from power,
1.
Place DIP switch S1-8 in the Off position.
2.
Leave it in the Off position for 10 seconds. This clears the non-volatile memory of the
Titled Output module.
3.
Return the switch to the ON position.
4.
Reinstall the module in chassis. When power is applied to the module, the module
defaults to a diagnostic mode and initializes defaults.
5.
Perform one of the following to clear the diagnostics:
Once again, remove the module from the chassis and reinstall it,
Remove power to the chassis and then power it back up while the module is
seated or,
Press the black reset button on the power module cover while the module is
seated
When power is reapplied to the module, the diagnostic mode is cleared.