Dip Switch Settings; Figure 8-4 Dip Switch Settings; Table 8-1 Dip Switch S1 And S2 Settings - Honeywell VideoBloX User Manual

Matrix switcher chassis only
Hide thumbs Also See for VideoBloX:
Table of Contents

Advertisement

DIP SWITCH SETTINGS

Rev 1.0
Figure 8-4
DIP Switch Settings
Set the Interlink Input DIP switches as follows:
Table 8-1
DIP Switch
S1.1
A0
S1.2
A1
S1.3
A2
S1.4
A3
S1.5
A4
S1.6
A5
S1.7
A6
S1.8
A7
S2.1
A8
S2.2
A9
S2.3
A10
S2.4
B0
S2.5
B1
S2.6
B2
S2.7
B3
S2.8
B4
Set the "Start Address" SW1 (1-8) and SW2 (1-3) to match the address of the first input
card within the connected sub-chassis.
Set S2 (4-8) to determine which group of 64 output signals this module will control.
For monitors 1-64, SW2/4 - SW2/8 should be set to 00000; for monitors 65-128 SW2/4
- SW2/8 should be set to 00001.