Volt Gfci; Light; Summer Mode - HotSpring Landmark Owner's Manual

Hide thumbs Also See for Landmark:
Table of Contents

Advertisement

LIGHT CONTROL
See Main Control Panel's Light Control section.

115 VOLT GFCI

The Ground Fault Circuit Interrupter is a safety device that is designed to detect as little as 5 milliamps (±1mA) of electrical
current leakage to ground. Watkins Manufacturing Corporation recommends that the GFCI be tested prior to each use to
ensure it is functioning correctly. With the spa connected to the power supply, push the TEST button. The spa should stop
operating and the GFCI power indicator will go out. Wait 30 seconds and then reset the GFCI by pushing the RESET button.
The GFCI power indicator will turn on, restoring power to the spa. If the interrupter does not perform in this manner, it is an indication of an
electrical malfunction and the possibility of an electric shock. Disconnect the plug from the receptacle until the fault has been identified and
corrected.
NOTE: Failure to wait 30 seconds before resetting the GFCI may cause the spa's POWER indicator (on the control panel) to blink. If this occurs,
repeat the GFCI test procedure.
CAUTION: Never use the GFCI as a means to disconnect power to the spa (always unplug it). If the GFCI is tripped while the spa is plugged in,
and a power outage occurs, when power returns the GFCI will automatically reset and power will flow to the spa.

LIGHT

®
All Hot Spring
Spas come equipped with a specially designed low voltage dimmable LED light to enhance nighttime use. The light source should
never need replacing in normal use.

SUMMER MODE

®
Your Hot Spring
Spa is equipped with a Summer Mode timer. The Summer Mode timer can be activated during extremely hot summer months if
it becomes difficult to maintain water temperatures low enough for comfort. Upon switching to the ON mode, the circulation pump (which can add
heat to the water through normal operation), heater and ozone (if installed) will immediately shut down for the next eight hours. Additionally, the
summer mode display on the main control panel will activate and remain active for as long as the summer mode is on. Following this eight hour
period, the circulation pump, heater, and ozone will automatically re-start and will operate normally for the next sixteen hours. The circulation
pump, heater and ozone will continue to turn off for an eight hour period every day that the switch remains in the ON position. In this way, the
amount of heat transferred to the spa water will be minimized. When the outside temperatures begin to cool, the Summer Mode timer should be
turned to the OFF position (the summer mode display on the main control panel will go out). This is the efficient 24 hour circulation mode that
keeps the heater operation and operating costs to a minimum during colder/heavier usage months.
NOTE: Whenever power is disconnected and then reconnected to the spa, the Summer Mode timer will reset starting with the 8-hour shutdown
mode. If a different 8-hour shut down time is desired, deactivate the Summer Mode, then reactivate at the beginning of the desired 8-hour shut
down time.
IMPORTANT: The Summer Mode will not lower the spa's water temperature below the ambient air temperature.
To activate the Summer Mode, simply follow these steps:
1. Set the temperature control to 80°F (26°C).
2. On the control panel, simultaneously press and hold for 3 seconds Temp Plus and Temp Minus buttons to activate the Summer Timer.
The Summer Mode must be deactivated when cooler temperatures return. To do this, simply repeat step 2.
WARNING: Failure to deactivate the Summer Mode when the temperature drops below 32°F will result in freezing of the spa. Damage resulting
from this situation is not covered under the terms of the warranty.