Item
Condition
7. RF power
1) RF power
_POW_XXX
Adjust the RF power.
All values in Low, Center and High
frequencies changes one time.
2) Select _ _L
_POW_XXX
in tune mode
PTT : ON
3) Select _ _C
_POW_XXX
in tune mode
PTT : ON
4) Select _ _H
_POW_XXX
in tune mode
PTT : ON
8. Maximum
1) CH-SIG : 1-1
deviation
Select MXDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF, LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/50mV
9. MIC
1) CH-SIG : 1-1
sensitivity
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 15kHz
De-emphasis : OFF
AG : 1kHz/5mV
10. QT
1) CH-SIG : 1-4
deviation
Select QTDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF
LPF : 3kHz
De-emphasis : OFF
11. DQT
1) CH-SIG : 1-6
deviation
Select DQDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF, LPF : 3kHz
De-emphasis : OFF
12. DTMF
1) CH-SIG : 1-8
deviation
Select DTDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF, LPF : 15kHz
De-emphasis : OFF
13. MSK
1) CH-SIG : 1-9
deviation
Select MSDV_XXX
in tune mode
PTT : ON
Deviation meter filter
HPF : OFF, LPF : 15kHz
De-emphasis : OFF
38
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Front
Ammeter panel
panel
Power meter Rear
ANT
Front
Deviation
panel
panel
meter
AF VTVM Front
MIC
AG
panel
Oscilloscope
TX-RX VR701 Check
(A/3)
Front
panel
Adjustment
Parts
Method
B key
70W
70w 1.0W
C key
15A or less
15A or less
B key
4.05kHz
C key
2.2~3.8kHz
B key
0.75kHz
C key
0.75kHz
3.0kHz
3.0kHz
Specifications/Remarks
0.1kHz
0.05kHz
0.05kHz
0.1kHz
0.1kHz