Kenwood TK-6110 Service Manual page 35

Hide thumbs Also See for TK-6110:
Table of Contents

Advertisement

Test Equipment Required for Alignment
No.
Test Equipment
1
Standard Signal Generator
(SSG)
2
Power Meter
3
Deviation Meter
4
Digital Volt Meter
(DVM)
5
Oscilloscope
6
High sensitivity
Frequency Counter
7
Ammeter
8
AF Volt Meter
(AFVTVM)
9
Audio Generator (AG)
10
Distortion Meter
11
Voltmeter
12
4
Dummy Load
13
Regulated Power Supply
Caution
Since the RX AF output is a BTL output, there is a DC
Component. Isolate this with a capacitor or transformer as
shown in the figure.
Tuning cable (E30-3383-05)
Adapter cable (E30-3383-05) is required for
injecting an audio if PC tuning is used.
See "PC Mode" section for the connection.
Lead wire +
Shiel wire –
MIC
ADJUSTMENT
Frequency Range
50kHz to 1000MHz.
Modulation
Frequency modulation and external modulation.
Output
0.1 V to greater than 1mV.
Input Impedance
50 .
Operation Frequency
50MHz or less.
Measurement Capability
Vicinity of 100W.
Frequency Range
29.7 to 50.0MHz.
Measuring Range
1 to 20V DC.
Accuracy
High input impedance for minimum circuit loading.
DC through 30MHz.
Frequency Range
10Hz to 200MHz.
Frequency Stability
0.2ppm or less.
30A.
Frequency Range
50Hz to 10kHz.
Voltage Range
3mV to 3V.
Frequency Range
50Hz to 5kHz or more.
Output
0 to 1V.
Capability
3% or less at 1kHz.
Input Level
50mV to 10Vrms.
Measuring Range
10 to 1.5V DC or less.
Input Impedance
50k /V or greater.
Approx. 4
(Adjustable from 9 to 17V, 30A).
Useful if ammeter equipped.
Test cable for speaker output
Major Specifications
30W.
Test cable for microphone input (E30-3360-08)
TK-6110
MIC connector
(Front view)
8
1
1 : BLC
2 : PSB
3 : E
4 : PTT
5 : ME
6 : MIC
7 : HOOK
8 : CM
35