1
8-3. Fixed shutter mode
When external trigger signal is POSITIVE (high active), after the trigger signal rise, exposure is
A
start. The exposure time is set by the camera electronic shutter speed. The video output is obtained
immediately after the end of fixed exposure. The strobe signal start/end can be set to shutter time.
Trigger signal input during exposure is disabled.
Trigger input
High
Low
(High active)
Shutter time
B
Strobe output
Data
VD
C
FVAL
8-4. ONE Trigger mode
When external trigger signal is POSITIVE (high active), after the trigger signal rise, exposure is start.
At the trigger signal falling edge, the internal VD signal is reset and the video data are transmitted. The
trigger signal width equals the exposure time.
D
Trigger
High
Low
input
Shutter time
E
Strobe output
Data output
VD
FVAL
F
1
2
More than 10μs.
Shutter time
(Camera setting value)
3H
37H
More than 10μs
More than 1252H
Shutter time
(Integration
3H
37H
2
3
More than 1252H
(*1)
(*1)
E400234503
DWG.
No.
3
4
SHEET
13
17
4
DF022-4PE-S1