Installation
(continued)
5. Connect water line. Recommended routing (Fig. 3) allows easy access
to water for cleaning and sanitizing procedure.
6. If installing the optional internal water fi lter*, please complete the
steps shown in
Cleaning and Sanitizing on page 11
proceeding. If not, proceed to step 10.
* If your dispenser has the internal water fi lter option, the water fi lter must be
installed for the dispenser to operate. Because internal components will need to
be accessed for both procedures, Follett recommends installing the water fi lter
just prior to initial sanitizing.
7.
Lift and remove the top panel, set aside (Fig. 4.1).
8. Remove two screws (Fig. 4.2) and remove left side panel.
9. Install fi lter as shown. Turn fi lter clockwise until it is fully seated
(Fig. 4.3).
10. Connect power supply.
11. Sanitize the dispenser prior to use (see
on page
11).
8
Undercounter Dispenser and Ice machine 7UC100A/7UD100A
–––––––––––––––––––––––––––––––––––––––––––––––––
Cleaning and Sanitizing
Fig. 3
3' (91.4 cm)
Fig. 4
before
2
Plug
Valve
1/4" MPT
1
3