Signal Check; Power Save Mode - Hitachi 37PD5000 User Manual

Color plasma display monitor
Hide thumbs Also See for 37PD5000:
Table of Contents

Advertisement

OTHER FEATURES (continued)

Signal Check

Changes in the signal status are displayed on the screen as they arise.
Status
When Mode Display is set to ON,
A guide is displayed for the input
the input signal is switched or
terminal and the horizontal and
when the RECALL button is
vertical sync frequency.
pressed.
When the sync signal is no longer
• A guide displays No Sync.
detected.
Signal, and Power Save (for
approx. 5 sec.)
• When the condition continues
where the sync signal cannot be
detected, indicator lamp of
power source changes in
orange and the mode switches
to power save mode.
When the input signal does not
A guide displays Invalid Scan
match the monitor specifications
Freq.
or is in an unstable status.

Power Save Mode

When the RGB1, RGB2 input is selected
• When this unit is connected to a VESA DPMS computer, the Power Save (Off) mode can be set to be activated automatically when the
computer is not being used to reduce power consumption by this unit.
RGB sync signal
PC signal
Operation mode
Indicating lamp
Power consumption
Returning to operating status
• Operate the personal computer, or press either the INPUT SELECT button of the main unit or the RGB1/RGB2 buttons of the remote control.
Display
Recheck the personal computer
power switch status and the
connection status.
Recheck the input signal
specifications.
Horizontal
Yes
Vertical
Yes
Active (normal display)
On
Lights green
320W (37")
530W (55")
RGB
Action
-- -- Min.
OFF
-- -- : -- --
No
Yes
Yes
No
Blank (no display)
Off
Lights orange
3W or less (RGB1)
1W or less (RGB2 ; 100V AC 120V)
3W or less (RGB2 ; 120V AC 240V)
RGB2
RGB
H : 48.4kHz
V : 60.1 Hz
! No Sync. Signal
! Invalid Scan Freq.
No
No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents