Ceiling Suspended Type - Daikin REYQ72 Serveice Manual

R-410a heat recovery 60hz
Table of Contents

Advertisement

Specifications

Ceiling Suspended Type

Model
1 Cooling Capacity
2 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Rows × Stages × FPI
Coil (Cross
Fin Coil)
Face Area
Model
Type
Fan
Motor Output
Air Flow Rate (H/L)
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Piping
Gas Pipes
Connections
Drain Pipe
Machine Weight (Mass)
4 Sound Level (H)
Safety Devices
Refrigerant Control
Connectable Outdoor Unit
Standard Accessories
Drawing No.
Notes:
1 Nominal cooling capacities are based on the following conditions:
2 Nominal heating capacities are based on the following conditions:
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
18
FXHQ12MVJU
Btu/h
12,000
Btu/h
13,500
White (10Y9/0.5)
in
7-11/16×37-13/16×26-3/4
2×12×15
ft²
1.96
3D12K1AA1
Sirocco Fan
W
62
CFM
410/340
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Wool
Resin Net (with Mold Resistant)
φ
in
1/4 (Flare Connection)
φ
in
1/2 (Flare Connection)
VP20
in
(External Dia. 1, Internal Dia. 3/4)
Lbs
55
dBA
42
Fuse
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation
Manual, Drain Hose, Paper Pattern for
Installation, Clamp Metal, Insulation
for Fitting, Clamps, Washers.
Return air temperature: 80°FDB, 67°FWB
Outdoor temperature: 95°FDB
Equivalent ref. piping: 25ft (Horizontal)
Return air temperature: 70°FDB.
Outdoor temperature: 47°FDB, 43°FWB
Equivalent ref. piping: 25ft (Horizontal)
these values are normally somewhat higher as a result of ambient conditions.
FXHQ24MVJU
24,000
27,000
White (10Y9/0.5)
7-11/16×55-1/8×26-3/4
3×12×15
3.15
3D12K2AA1
Sirocco Fan
130
710/600
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Wool
Resin Net (with Mold Resistant)
φ
3/8 (Flare Connection)
φ
5/8 (Flare Connection)
VP20
(External Dia. 1, Internal Dia. 3/4)
80
44
Fuse
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation
Manual, Drain Hose, Paper Pattern for
Installation, Clamp Metal, Insulation
for Fitting, Clamps, Washers.
4D049326
SiUS39-602
FXHQ36MVJU
36,000
40,000
White (10Y9/0.5)
7-11/16×62-5/8×26-3/4
2×12×15+2×10×15
3.66+2.95
3D12K2AA1
Sirocco Fan
130
830/670
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Wool
Resin Net (with Mold Resistant)
φ
3/8 (Flare Connection)
φ
5/8 (Flare Connection)
VP20
(External Dia. 1, Internal Dia. 3/4)
90
46
Fuse
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation
Manual, Drain Hose, Paper Pattern for
Installation, Clamp Metal, Insulation
for Fitting, Clamps, Washers.
Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents