Error Code Error Message
0082h
Secondary Master
Drive-ATAPI
Incompatible
0083h
Secondary Slave Drive-
ATAPI Incompatible
0166h
CPU Frequency
mismatch!
0167h
CPUID mismatch!
0168h
L1 cache size mismatch! CPU mix installed is not
0169h
L2 cache size mismatch! CPU mix installed is not
016Ah
CPU Patch level
mismatch!
4168h
DIMM CRC Error or be
ignore POST Error
4169h
DIMM Chip Select
Disable, Test Fail
5120h
CMOS cleared by
jumper
5122h
Password cleared by
jumper
8104h
Warning! Port 60h/64h
emulation is not
supported by this USB
Host Controller!!!
8105h
Warning! EHCI
controller disabled. It
requires 64 bit data
support in the BIOS.
8601h
Error: BMC Not
Responding
8701h
Insufficient Runtime
space for MPS data!!
System may operate in
PIC or Non-MPS mode.
8702h
No enough APIC ID in Check APIC failed
Error Cause
HDD/ATAPI/IDE device
failure
HDD/ATAPI/IDE device
failure
CPU mix installed is not
support
CPU mix installed is not
support
support
support
CPU mix installed is not
support
DIMM bad
DIMM bad
CMOS clear by jumper
Password clear by jumper No action
Not supported by the HC Board repair
Check whether this host
controller needs 64 bit
data structure or not
BMC chip does not find Board repair
Failed to copy the
MPTable to F000 or
E000 shadow RAM
Recovery Method
Change HDD
Change HDD
Install same model
CPU
Install same model
CPU
Install same model
CPU
Install same model
CPU
Install same model
CPU
Change DIMM
Change DIMM
No action
Board repair
Board repair
Board repair
About Your System | 27