ArbStudio
Signals Description (Pattern Generator, Optional)
The signals available on ArbStudio 1102D/1104D Pattern Generator/Sampler connectors are reported as follows:
Signal Name
Type
DGND
Input
DP[0..17]
Output
Input /
DP[15] / CLK
Output
DP[16] / EXT
Input /
TRG
Output
DP[17] / WR
Input /
RAM
Output
DC_TO
Output
DC_TI
Input
The Pulse Width Modulation (PWM) Generator Workspace
Overivew
The PWM Generator consists of three main elements:
• The Pulse Definition Area ‐ Provides access to pulse waveform parameters.
• The Duty Cycle Modulation Area ‐ Where you can define the modulation law changing the modulating
shape of the duty cycle and its parameters.
118
Digital pattern generator bidirectional pins
Clock generator module output pin or additional input pin
Extended Trigger output pin or additional input pin
Write Ram signal used as output pin or additional input pin
Pattern Generator Trigger Out signals are sent to DC_TO pins on Pod A/Pod B
When DC Trigger IN Source is enabled (see Settings →Trigger IN menu),
trigger in signal of Pod A Pattern is acquired from DC_TI pin on Pod A, trigger in
signal of Pod B Pattern is acquired from DC_TI pin on Pod B.
Description
Digital ground
Digital Connector Trigger out.
probes.
Digital Connector Trigger IN.
918221 RevA