Error Conditions

975-0209-01-01
When an error condition occurs, the LED will flash red, followed by a five-second
rest period. You can identify error conditions by counting the number of times the
LED flashes before turning off for five seconds. The following table lists LED
flashing patterns and their associated error conditions.
Table 3-3 LED activity and Error Conditions
Number
of Flashes Error Condition
1
Low battery voltage
2
High battery voltage
3
Inverter over-
temperature
4
Battery charger fault
6
Generator start fault
8
Internal sensor error
9
Internal memory
error
a.Because voltages vary according to the load on the inverter , all voltages in this
table are ±0.3 V.
Cause
Battery voltage has fallen to 10.5 V
Series stops inverting. This error clears when the
voltage rises to 11.6 V.
Battery voltage has risen to 15.7 V. The RV Series
stops inverting. This error clears when the voltage
rises to 15.4 V.
The FET and transformer temperature has risen to
194°F (90°C). The RV Series stops inverting or
charging. This error clears when the temperature
falls below 194°F (90°C).
Charger not charging correctly.
The RV Series has tried to start the generator three
times without detecting a B+ signal.
Analog-digital converter is faulty.
Internal processor is faulty.