NTI UNIMUX SERIES USB KVM SWITCH
RACKMOUNTING INSTRUCTIONS
This NTI switch was designed to be mounted to a rack or to sit on a desktop. It includes rackmount ears to make attachment to a
rack easy, and rubber feet to be applied to the bottom of the case if it will instead sit on a flat surface.
surface, simply apply the rubber feet to the bottom of the case in each of the 4 corners.
To Mount to a Rack
1.
Attach the ears to the switch using the 6-32x3/16" flat Phillips-head screws (6) provided as shown in the illustration below.
The holes in the ears should line up with pre-threaded holes in the sides of the NTI switch.
2.
Install 4 captive nuts (not provided) to the rack in locations that line up with the holes in the mounting ear on the NTI switch.
3.
Secure the NTI switch to the rack using four 3/16" diameter screws (not provided).
to go completely through the NTI mounting ear, rack frame and fully engage all threads in the captive nut.
tighten all mounting screws securely.
4.
Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.
NTI Switch
Front of Switch
Figure 1- Secure rackmount ears to switch
NTI Switch
3/16" Diameter Screws
(not provided)
Figure 2- Secure switch to a rack
6-32x3/16"
Flat Head
Screws
(Provided)
Rackmount Ear
Each screw should be of sufficient length
Rack
Captive Nuts
(not provided)
4
If this will sit on a flat
Tighten the screws securely.
Be sure to