Installation; Unpacking; Package Contents; Location - GE LanPro 11 U User Manual

Lanpro 11 u 5/6/8/10 kva
Table of Contents

Advertisement

g
4.1

Unpacking

Cut the two wrapping bands, and remove the shipping box. Loosen the four bolts with which the UPS is fixed to the
pallet. Remove the UPS from the pallet.
UPS is equipped with castors, that allow easy displacement of the unit. Please take appropriate measures to avoid
damage on vulnerable floors.
4.2

Package Contents

The shipping box contains a LanPro
safety guide and this manual. If the UPS is equipped with an RPA plug-in card (Redundant Parallel Architecture,
right option slot at the rear of the unit) the shipping box also contains a yellow network cable and one bus terminator.
Inspect the UPS for damage after unpacking. If any damage is present please notify the carrier and place of
purchase immediately.
4.3

Location

Please refer to section 1.3 of 'IMPORTANT SAFETY INSTRUCTIONS'.
4.4

Installation

IMPORTANT
:
Before making any connection and switching on the LanPro
The voltage and frequency of your utility supply is 120/208/230/240 Vac and 50 or 60 Hz; from the factory the
input and output of the UPS are set to 208 Vac / 60 Hz.
Be sure that the UPS is wired for the present utility voltage. This is indicated on the packaging of the UPS, as
well as at the I/O terminals.
Overcurrent protection for the AC circuit is to be provided by others.
CAUTION:
UPS model
Operating input voltage
L5-11U
L5-11U /120V
L6-11U
L6-11U /120V
L8-11U
L10-11U
Table 1. external input fuse value
Ensure that the total power requirement of the equipment to be protected does not exceed the rated output
power of the UPS. (output power for your unit is indicated on the rating label on the rear panel).
When using the 120V split phase outputs make sure that the load per 120V output does not exceed half the
rating.
The UPS may only be installed by trained personnel. The UPS must be grounded when in use: Connect the
UPS to a single phase, three wire AC source equipped with an earth connection.
LX: OPM_LPA_11U_5K0_10K_1US_V021
4 - Installation
BE CAREFUL! HEAVY WEIGHT!
®
-U UPS, a CD-ROM, an RS232 cable, a link (5/6kVA models only, see 4.4.3) a
To reduce risk of fire, connect only to a circuit input/output provided with
branch circuit overcurrent protection in accordance with the National Electrical
Code, ANSI / NFPA 70, as indicated below:
Input overcurrent protection
(Amps)
120V
208V
35
60
40
70
60
70
8
Never try to lift the unit by yourself! The
®
-U UPS, please check the following conditions:
Output overcurrent protection
240V
120V
120V
(1 X)
(2X)
30
40
40
35
50
50
45
70
60
80
GE DE LanPro-11U UPS: Installation / User Manual 2.1 (US)
GE Digital Energy
(Max. Amps)
208V
240V
20
25
20
20
25
20
25
30
25
25
30
25
35
40
35
40
50
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents