5.1.29 Fan Motor 60 Unit
(1) Remove the three bind B M4x12, taptite screws and three FG harness ASSY 1, 4, 5.
(2) Remove the base plate.
Taptite, bind B M4x12
FG harness ASSY 1
FG harness ASSY 5
Printer top side
(Printer body
upside down)
(3) Release the harness from the hook, and then remove the fan motor 60 unit from the main
frame R.
CAUTION: When re-assembling the fan motor 60 unit, make sure to turn the side with a
Chute
label outwards.
Hooks
Main frame R
5-57
FG harness ASSY 4
Base plate
Fan motor 60 unit harness
Hooks
Fan motor 60 unit
Label
Confidential