Rack or Wall Mounting (SF400/800)

The MultiModem SF400/800 units can be rack (or wall) mounted with screws using the mounting brackets.
Rack Mounting
Ensure proper installation of the unit in a closed or multi-unit enclosure by following the recommended installation as
defined by the enclosure manufacturer. Do not place the unit directly on top of other equipment or place other
equipment directly on top of the unit. If installing the unit in a closed or multi-unit enclosure, ensure adequate airflow
within the rack so that the maximum recommended ambient temperature (50° C) is not exceeded. Ensure that the unit is
properly connected to earth ground by verifying that it is reliably grounded when mounted within a rack. If a power strip
is used, ensure that the power strip provides adequate grounding of the attached apparatus.
When mounting the equipment in the rack, make sure mechanical loading is even to avoid a hazardous condition. The
rack used must safely support the combined weight of all the equipment it supports.
Ensure that the mains supply circuit is capable of handling the load of the equipment. See the power label on the
equipment for load requirements.
Ensure that only properly qualified service personnel install this equipment. Only connect like circuits - connect SELV
(Secondary Extra Low Voltage) circuits to SELV circuits and TN (Telecommunications Network) circuits to TN circuits.
Note:
The ambient temperature of the rack interior must not exceed 50° Celsius.
19-Inch Rack Enclosure Mounting Procedure
Two people may need to work together to attach the MultiModem iSMS to the rail of an EIA 19-inch rack. These people
must attach the brackets to the MultiModem iSMS chassis with the screws provided, as shown in the figure above, and
then secure unit to rack rails by the brackets.
Because equipment racks vary, screws for rack-rail mounting are not provided. Follow the instructions of the rack
manufacturer and use screws that fit.
Position the right rack-mounting bracket on the MultiModem iSMS using the two vertical mounting screw holes.
1.
Secure the bracket to the MultiModem iSMS using the two screws provided.
2.
Position the left rack-mounting bracket on the MultiModem iSMS using the two vertical mounting screw holes.
3.
Secure the bracket to the MultiModem iSMS using the two screws provided.
4.
Remove feet (4) from the MultiModem iSMS unit.
5.
Mount the MultiModem iSMS in the rack enclosure per the rack manufacture's mounting procedure.