Fuser Unit Disassembly - Epson EPL-6200 Service Manual

A4 monochrome page printer
Hide thumbs Also See for EPL-6200:
Table of Contents

Advertisement

EPSON EPL-6200/EPL-6200L

4.5.2 Fuser Unit Disassembly

Do not touch the glass of the heater lamp with bare hands.
When you remove the Fusing Separation Claw, take care not to
lose the spring.
To avoid scratching the Fusing Roller surface by the Fusing
Separation Claw, keep the Fusing Separation Claw lifted when
removing or installing the Fusing Roller.
1.
Remove the Fuser Unit. (p.152)
2.
Remove the two screws, and separate the Fuser Unit.
3.
Remove the two shaft holders, and remove the Pressure Roller.
4.
Remove the one screw, and remove the terminal board.
5.
Pull out the Fusing Roller Heater Lamp.
6.
Pull off the driving gear from the Fusing Roller.
7.
Pull out the Fusing Roller.
8.
Remove the four Fusing Separation Claws.
9.
Remove the one screw, and remove the Thermistor.
10. Remove the two screws, and remove the Thermostat.
When installing the Thermistor, lead the harness as shown at
right.
Install the Fusing Roller Heater Lamp so that the voltage
indicator faces the gear side.
Install the shaft holder so that the groove in the shaft holder is
put on the rib of the Fuser Unit.
Disassembly and Assembly
Removal and Installation of Major Components
Figure 4-35. Disassembling the Fuser Unit
Revision A