Upper Latch Switch And Monitor Switch (United Kingdom And Australia) Removal; Lower Latch Switch Removal - Sharp R-8000E Service Manual

Convection microwave oven
Table of Contents

Advertisement

UPPER
LATCH
SWITCH
AND
MONITOR
SWITCH
(United Kingdom and Australia)
REMOVAL
1.
Disconnect
the
oven
from
the
power
supply
and
remove the outer case.
2.
Discharge the high voltage capacitor.
3.
Remove the complete control panel assembly, referring
to the Control
Panel Assembly
and Component
Re-
moval.
4.
Disconnect the wire leads from the switches.
5.
Remove the single (1) screw and washer holding
the
upper latch hook to the oven cavity front flange.
6.
Remove the upper latch hook from the flange by mov-
ing it downward.
7.
To remove the switch from the upper latch hook, push
outward
the two (2) retaining
tabs holding the switch
in place.
LOWER
LATCH
SWITCH
REMOVAL
1.
Disconnect
the
oven
from
the
power
supply
and
remove the outer case.
2.
Discharge the high voltage capacitor.
3.
Remove the complete control panel assembly, referring
to the Control
Panel Assembly
and Component
Re-
moval.
4.
Disconnect
the wire leads from the switches.
5.
Remove
the single (1) screw and washer holding
the
lower latch hook to the oven cavity front flange.
6.
Remove the lower latch hook from the flange by mov-
ing it downward.
7.
Disconnect
the wire leads from the switch.
8.
Push outward
the two (2) retaining
tabs holding the
switch in place.
9.
The switch is now free.