Hill Phoenix ONRB Installation & Operation Handbook page 33

Hill phoenix reach-in beverage orb, orbh, onrb, onrbh handbook installation & operation
Table of Contents

Advertisement

High Narrow Glass Door Reach-in Beverage Merchandiser
ONRBH - 2, 3, 4 & 5-door
Electrical Data
Fans per
Case
Model
ONRBH
2-door
2
3-door
3
4-door
4
5-door
5
Lighting Data
Typical per
Light Row
120 Volts
Model
Amps
Watts
1
ONRBH
2-door
NA
3-door
NA
4-door
NA
5-door
NA
1
Not applicable.
Guidelines & Control Settings
Model
BTUH/door
2
4
ONRBH
-
830
Deli/Dairy
2
ONRBH
-
4
800
Beverage
2
All data listed is for an ONRBH configured with 20" shelves.
3
BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04.
4
High efficiency fans reduce refrigeration load by 96 BTUHs/fan.
5
Average discharge air velocity at peak of defrost.
Defrost Controls
Defrosts
Run-Off
Model
Per Day
Time (min)
6
ONRBH
4
6 - 8
6
If timed off defrost is utilized. If electric or hot gas defrost is utilized case only requires 1 defrost per day.
7
NOTE: - - - not an option on this case model.
Medium Temperature Defrost Schedule
No. Per Day
Hours
1
12 midnight
2
12 am - 12 pm
3
6 am - 2 pm - 10 pm
4
12 - 6 am - 12 - 6 pm
All measurements are taken per ARI 1200 - 2002 specifications.
High Efficiency
Standard Fans
Fans
120 Volts
120 Volts
Amps
Watts
Amps
1.00
60
0.31
1.50
90
0.46
2.00
120
0.61
2.50
150
0.77
Maximum
Lighting
120 Volts
Amps
Watts
NA
1.50
180
NA
1.90
228
NA
2.40
288
NA
2.90
348
Superheat Set
Coil
Evaporator
Point @ Bulb (
Type
(°F)
3
Enh.
32
Enh.
34
Electric Defrost
Fail-safe
Termination
(min)
Temp. (°F)
30
47
Anti-Condensate
Heaters
120 Volts
Watts
Amps
Watts
18.4
1.06
127
27.6
1.55
186
36.8
2.07
248
46.0
2.54
305
Return Air
Discharge Air
o
F)
(°F)
6-8
36
6-8
38
Timed Off Defrost
Hot Gas Defrost
Fail-safe
Termination
Fail-safe
(min)
Temp. (°F)
(min)
30
40
24
29
Defrost Heaters
208 Volts
240 Volts
Amps
Watts
Amps
Watts
4.39
914
5.06
1215
4.96
1032
5.71
1370
6.51
1355
7.55
1813
7.96
1655
9.17
2201
Discharge Air Velocity
(°F)
(FPM)
38
405
40
405
Reverse Air Defrost
Termination
Fail-safe
Termination
Temp. (°F)
(min)
7
47
- - -
5
Temp. (°F)
- - -
COMPONENT