Control Setting Guideline - Pages; Case Operation; Electrical Data; Defrost Controls - Hill Phoenix ONRB Installation & Operation Handbook

Hill phoenix reach-in beverage orb, orbh, onrb, onrbh handbook installation & operation
Table of Contents

Advertisement

CASE OPERATION

Glass Door Reach-in Beverage Merchandiser
ORB - 2, 3, 4, 5 & 6-door

Electrical Data

Standard Fans
Fans
per
Model
Case
Amps
ORB
2-door
2
1.00
3-door
3
1.50
4-door
4
2.00
5-door
5
2.50
6-door
6
3.00
Lighting Data
Typical per
Light Row
120 Volts
Model
Amps
Watts
1
ORB
2-door
NA
3-door
NA
4-door
NA
5-door
NA
6-door
NA
1
Not applicable.
Guidelines & Control Settings
Model
BTUH/door
ORB -
830
Deli/Dairy
ORB -
Beverage
800
2
BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04.
3
High efficiency fans reduce refrigeration load by 96 BTUHs/fan.
4
Average discharge air velocity at peak of defrost.

Defrost Controls

Defrosts
Run-Off
Model
Per Day
Time (min)
5
ORB
4
6 - 8
5
If timed off defrost is utilized. If electric or hot gas defrost is utilized case only requires 1 defrost per day.
6
NOTE: - - - not an option on this case model.
Medium Temperature Defrost Schedule
No. Per Day
Hours
1
12 midnight
2
12 am - 12 pm
3
6 am - 2 pm - 10 pm
4
12 - 6 am - 12 - 6 pm
All measurements are taken per ARI 1200 - 2002 specifications.
High Efficiency
Fans
120 Volts
120 Volts
Watts
Amps
Watts
60
0.31
18.4
90
0.46
27.6
120
0.61
36.8
150
0.77
46.0
180
0.92
55.2
Maximum
Lighting
120 Volts
Amps
Watts
NA
1.50
180
NA
1.90
228
NA
2.40
288
NA
2.90
348
NA
3.40
408
Superheat Set
Coil
Evaporator
Point @ Bulb (
Type
(°F)
2
3
Enh.
32
3
Enh.
34
Electric Defrost
Fail-safe
Termination
(min)
Temp. (°F)
30
47
Anti-Condensate
Heaters
120 Volts
208 Volts
Amps
Watts
Amps
1.01
121
4.39
1.49
179
4.96
1.96
235
6.51
2.40
288
7.96
2.92
350
9.40
Return Air
Discharge Air
o
F)
(°F)
6-8
36
6-8
38
Timed Off Defrost
Hot Gas Defrost
Fail-safe
Termination
Fail-safe
(min)
Temp. (°F)
(min)
30
40
24
26
Defrost Heaters
240 Volts
Watts
Amps
Watts
914
5.06
1215
1032
5.71
1370
1355
7.55
1813
1655
9.17
2201
1955
10.79
2589
Discharge Air Velocity
(°F)
(FPM)
38
380
40
380
Reverse Air Defrost
Termination
Fail-safe
Termination
Temp. (°F)
(min)
Temp. (°F)
6
47
- - -
4
- - -