Summary of Contents for Hill Phoenix ONRB

  • Page 1 REACH-IN BEVERAGE C A S E S M O D E L : O R B , O R B H , O N R B & O N R B H INSTALLATION & OPERATION HANDBOOK P057333G Rev. 12 6/06 COMPONENT...
  • Page 3 We are interested in your suggestions for improvement both in case design and in this handbook. Please call/write to: Hill PHOENIX Marketing Services Department 1925 Ruffin Mill Rd. Colonial Heights, VA 23834...
  • Page 5: Table Of Contents

    TABLE OF CONTENTS GENERAL INFORMATION – PAGES 3 - 8 General information, first step recommendations and case dimensional drawings. THE USE OF CASTERS – PAGE 9 Cases roll on casters–general use and caster removal. LINE-UP – PAGES 10 - 11 A twelve step procedure for initial case lineup with illustrations.
  • Page 7: General Information - Pages

    15 days of receipt of equipment. LOST ITEMS: This equipment has been carefully inspected to insure the highest level of quality. Any claim for lost items must be made to Hill PHOENIX within 48 hours of receipt of equipment. TECHNICAL SUPPORT: If any technical questions arise regarding a refrigerated display case contact our Customer Service Department in Richmond at 1-804-526-4455.
  • Page 8 GENERAL INFORMATION 81 1/4 in [206.3 cm] 83 1/4 in [211.5 cm] 5 1/8 in [13.1 cm] 8 in [20.3 cm] 10 in [25.4 cm] 31 9/16 in [80.2 cm] 34 11/16 in [88.1 cm] 42 11/16 in [108.4 cm] JUNCTION BOX (STANDARD) 16 1/16 in [40.8 cm]...
  • Page 9 41 7/16 in [105.2 cm] 85 1/16 in [216.0 cm] 87 1/16 in [221.1 cm] 30 7/8 in [78.4 cm] COIL 6 13/16 in [17.2 cm]* 5 1/8 in [13.1 cm] 31 9/16 in [80.2 cm] 39 1/4 in [99.7 cm] 42 11/16 in [108.4 cm] WIRING-TO-TOP (OPTIONAL)
  • Page 10 3 3/8 in [8.6 cm] 23 1/4 in [59.1 cm] 4 in [10.2 cm] 26 7/8 in [68.3 cm] 31 7/8 in [81.0 cm] REFRIGERATION 1 1/2 in [3.8 cm] {END} 8 11/16 in [22.1 cm] 1 1/2" PVC DRAIN CONNECTION MODEL ONRB...
  • Page 11 85 1/16 in [216.0 cm] 87 1/16 in [221.1 cm] 6 13/16 in [17.3 cm]* 5 1/8 in [13.1 cm] 24 3/16 in [61.4 cm] WIRING-TO-TOP 8 in [20.3 cm] (OPTIONAL) 10 in 27 5/16 in [25.4 cm] [69.4 cm] 24 3/16 in [61.4 cm] 35 3/8 in...
  • Page 12: General Information

    132 13/16" 4" 31 11/16" STANDARD 4" 31 11/16" STANDARD 6" 4" 149 1/4" FRONT OF CASE 4" 6" 179 1/4" FRONT OF CASE BASEHORSE LOCATION FOR MODEL ONRB, ONRBH, ORB & ORBH 31 11/16" STANDARD 4" 31 11/16" STANDARD...
  • Page 13: The Use Of Casters

    CASES MOVE ON CASTERS FOR EASIER INSTALLATION ORIGIN 2 cases are manufactured and shipped to stores with casters installed on the base frame to make the job of moving cases easier for everyone involved with the manufacturing, shipping and instal- lation process.
  • Page 14: Line-Up - Pages

    LINE UP Consult With General Contractor Ask the general contractor if there have been changes in the building dimensions since the print you are using was issued. Also, ask the points of reference from which you should take dimensions to locate the cases.
  • Page 15 Ask about our case installation video available by request through your local Hill PHOENIX Sales or Field Service Representative. Position Next Case In Line Up Roll case approximately 6’ from adjoining case. Remove casters on the end nearest to the next case.
  • Page 16: Trim-Out - Pages

    TRIM OUT Now that cases have been positioned and leveled, you may proceed to trim-out case line- up. Trim parts have been designed to be applied easily with only a small number of fas- teners required. Most external parts are adjustable to achieve almost invisible, snug-fit- ting joints and a high level of excellence in fit and finish.
  • Page 17 Insert exterior cornice joint at every case joint. The exterior cornice joints are shipped loose with each case STREAMLYNE MASTER BUMPER MASTER BUMPER BRACKET Place the hook of the Streamlyne bumper on the lip of the master bumper bracket and rotate the bumper down while pushing it in.
  • Page 18: Refrigeration Piping

    ** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS SUCTION LINE (ALL LENGTHS) 1/2" LIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2" MODEL ORB, ORBH, ONRB & ONRBH NARROW 6 DOOR SUPPORT EXTRA FRAME SUPPORT...
  • Page 19: Plumbing

    150 in [381.0 cm] {5 Door} 180 in [457.2 cm] {6 Door} 96 in [243.8 cm] {8' case} 144 in [365.8 cm] {12' case} MODEL ORB, ORBH, ONRB & ONRBH LIFT UP FROM “J” RAIL AND PULL OUT KICKPLATE PLUMBING...
  • Page 20: Electrical Hookup And Wiring Diagrams - Pages

    96 in [243.8 cm] {8' case} NOTES: 144 in [365.8 cm] {12' case} ** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS WIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT MODEL ORB, ORBH, ONRB & ONRBH WIRE NUMBER COLOR CODING WHITE BLACK WHITE...
  • Page 21 The electronic ballasts that operate the vertical prism door lights are located in the door frame for Anthony ® door frames. MULLION 1 . CORNER BEAD 2. ACCESS COVER STEPS TO REPLACE THE BALLAST ANTHONY 1. REMOVE CORNER BEADS (2) 2.
  • Page 22 BALLAST LOCATIONS POWER LEADS FILTER BALLAST FOR LAMP 2 BALLAST FOR LAMPS 1 & 3 LAMP LEADS POWER LEADS BALLAST FOR LAMPS 1 & 2 LAMP LEADS 2 DOOR MODELS FILTER BALLAST FOR LAMPS 3 & 4 3 DOOR MODELS...
  • Page 23 4 DOOR MODELS BALLAST FOR LAMPS 1 & 2 5 DOOR MODELS BALLAST FOR LAMPS 1 & 2 POWER LEADS FILTER BALLAST FOR BALLAST FOR LAMP 3 LAMPS 4 & 5 LAMP LEADS POWER LEADS BALLAST FOR LAMPS 3 & 4 LAMP LEADS FILTER BALLAST FOR...
  • Page 24: Wiring Diagrams

    WIRING DIAGRAMS- ORB, ORBH, ONRB & ONRBH 2 DOOR...
  • Page 25 WIRING DIAGRAMS- ORB, ORBH, ONRB & ONRBH 3 DOOR - 8’...
  • Page 26 WIRING DIAGRAMS- ORB, ORBH, ONRB & ONRBH 4 DOOR - 12’...
  • Page 27 WIRING DIAGRAMS- LAMP LAMP LAMP LAMP LAMP LAMP BLACK WHITE ORB, ORBH, ONRB & ONRBH 5 DOOR FANS 120V WHITE USED BLUE 208/240V DEFROST YELLOW ROOM COMP. YELLOW PURPLE ROOM COMP. ORANGE BLACK LIGHTS 120V WHITE BLACK HEATERS COND. ANTI-...
  • Page 28 WIRING DIAGRAMS- LAMP LAMP LAMP LAMP LAMP LAMP LAMP YELLOW YELLOW BLACK BLACK WHITE WHITE ORB & ORBH 6 DOOR FANS 120V WHITE USED BLUE 208/240V DEFROST ROOM COMP. PURPLE ROOM COMP. ORANGE BLACK LIGHTS 120V WHITE HEATERS COND. ANTI- GREEN...
  • Page 29 WIRING DIAGRAMS-...
  • Page 30: Control Setting Guideline - Pages

    CASE OPERATION Glass Door Reach-in Beverage Merchandiser ORB - 2, 3, 4, 5 & 6-door Electrical Data Standard Fans Fans 120 Volts Model Case Amps Watts 2-door 1.00 3-door 1.50 4-door 2.00 5-door 2.50 6-door 3.00 Lighting Data Typical per Maximum Light Row Lighting...
  • Page 31 High Glass Door Reach-in Beverage Merchandiser ORBH - 2, 3, 4, 5, 6-door, 8’ & 12’ Electrical Data Standard Fans 120 Volts Fans per Case Model Amps ORBH 2-door 1.00 3-door 1.50 4-door 2.00 5-door 2.50 6-door 3.00 8’ 1.50 12’...
  • Page 32 ONRB Enh. Beverage All data listed is for an ONRB configured with 20” shelves. BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04. High efficiency fans reduce refrigeration load by 96 BTUHs/fan.
  • Page 33 High Narrow Glass Door Reach-in Beverage Merchandiser ONRBH - 2, 3, 4 & 5-door Electrical Data Standard Fans 120 Volts Fans per Case Model Amps ONRBH 2-door 1.00 3-door 1.50 4-door 2.00 5-door 2.50 Lighting Data Typical per Maximum Light Row Lighting 120 Volts 120 Volts...
  • Page 34: Defrost And Temperature Control

    DEFROST This case is equipped with either Electric, Hot Gas, or Timed-Off defrost at the owners option. The sensor bulb and probe for electric defrost termination control, the sensor bulb for timed-off defrost termination control, and the sensor bulb for temperature control are all located behind the rear baffle at the location shown in illustration 1 below.
  • Page 35: Product Loading

    Please keep products within the load limit lines shown on these diagrams. DISCHARGE...1 LOAD LIMIT...2 AIR FLOW...3 RETURN AIR GRILL...4 MODEL ORB, ORBH, ONRB & ONRBH...
  • Page 36: Use And Maintenance - Pages

    CASE CLEANING Case is designed to facilitate cleaning. There is a wide radius formed on the front and back of the inside bottom of the tank (ORB & ORBH) that helps accelerate liquid flow and eliminates difficult-to-clean sharp corners. All surfaces pitch to a deep-drawn drain trough that angles toward the front and center of case where the waste outlet is located for easy access.
  • Page 37 2. Remove two fasteners, then lift out the entire fan basket MAINTENANCE Model Fans Blade Pitch 2 DOOR 3 DOOR - 8’ 6 DOOR (2) ORB, ORBH, ONRB, & ONRBH 2 Door 3 Door 4 Door 5 Door Model Fans Blade Pitch 4 DOOR - 12’...
  • Page 38: Parts Ordering - Pages

    PARTS ORDERING...
  • Page 39 Model ORB, ORBH, ONRB & ONRBH Location Part Descriptions Number Kickplate, Storm Grey Master Bumper, 3/4, 1/2, Featherstone, Smoke, White, French Vanilla, Black Lower Front Panel, Painted Custom Color (Not Shown) Color Band, Painted Custom Color or Stainless Deck Pan, Painted, Unpainted...
  • Page 40: Parts Ordering

    (See illustrations on pages 4-7). 3. If parts are to be returned for credit, ask the Parts Department to furnish you with a Return Materials Authorization Number. Hill PHOENIX 1925 Ruffin Mill Road Colonial Heights, Virginia 23834 Tel: 800-283-1109...
  • Page 41: Appendix A

    CLEANING INSTRUCTIONS FOR ANTIFOG COATING Antifog Coating Cleaning Instructions (ANTIFOG B): Materials CAUTION: 1. Only use deionized or distilled water with 2% cleaning solution (P/N 05-14700-0001) to clean the antifog coating. Do not apply cleaning solution full strength! Do not use commercial glass cleaners containing ammonia or alcohol.
  • Page 42: Notes

    NOTES...
  • Page 43: Use And Maintenance

    Judged to be Defective in Material or Workmanship States Our Entire Liability Whether Based on Tort, Contract or Warranty. We Neither Assume Nor Authorize Any Other Person to Assume for Us Any Other Liability in Connection with Our Product. MAIL CLAIM TO: Hill PHOENIX Display Merchandisers 1925 Ruffin Mill Road Colonial Heights, VA 23834...
  • Page 44 Due to our commitment to continuous improvement all specifications are subject to change without notice. ASH6060 Warning 1925 Ruffin Mill Road, Colonial Heights, VA 23834 Hill PHOENIX is a Sustaining Member of the American Society of Quality. Visit our web site at www.hillphoenix.com...

Table of Contents