Oam Configuration Example - H3C S9500 Series Operation Manual

Routing switches
Hide thumbs Also See for S9500 Series:
Table of Contents

Advertisement

Operation Manual – Ethernet OAM
H3C S9500 Series Routing Switches
Clear statistics on OAM
packets and OAM link error
events

1.7 OAM Configuration Example

I. Network requirements
Enable OAM on Switch A and Switch B to manage links on data link layer.
Monitor link performance and collect statistics about the error frames received by
Switch A.
II. Network diagram
Figure 1-2 Network diagram for OAM configuration
III. Configuration procedure
1)
Configure Switch A
# Configure Ethernet 4/1/2 to operate in passive OAM mode and enable OAM for it.
<Sysname> system-view
[Sysname] interface ethernet 4/1/2
[Sysname-Ethernet4/1/2] oam mode passive
[Sysname-Ethernet4/1/2] oam enable
[Sysname-Ethernet4/1/2] quit
# Set the period for error frame event detection to 20 seconds.
[Sysname] oam errored-frame period 20
# Set the threshold for error frame event detection to 10.
[Sysname] oam errored-frame threshold 10
# Display global OAM configuration.
To do...
Use the command...
reset oam [ interface
interface-type
interface-number ]
1-9
Chapter 1 OAM Configuration
Remarks
Available in user
view only

Advertisement

Table of Contents
loading

Table of Contents