1-3. TROUBLESHOOTING

PROBLEM
With the switch in
the ON position,
fryer is completely
inoperative
Shortening will not
heat but lights are on
1-2
To isolate a malfunction, proceed as follows:
1. Clearly define the problem or symptom and when it
occurs.
2. Locate the problem in the Troubleshooting table.
3. Review all possible causes, then one at a time work
through the list of corrections until the problem is solved.
If maintenance procedures are not followed correctly,
injuries and/or property damage could result.
CAUSE
• Open circuit
• Faulty contactor
(elec. model)
• Faulty gas control
valve (gas model)
• Faulty temperature
probe
• Faulty high limit
• Faulty drain switch
Model OFE/OFG/OEA/OGA-341, 342
CORRECTION
• Check to see if unit is plugged in
• Check breaker or fuse at supply box
• Check power switch per Power Switch
Section; replace if defective
• Check voltage at wall receptacle
• Check cord and plug
• Check contactor per Heating Contactors
Section
• Check gas control valve per Gas Control
Valve Assembly Section
• Check temperature probe per Temperature
Probe Replacement Section; "E6"
• Check high limit per the appropriate High
Temperature Limit Control Section; "E10"
• Check drain switch per Drain Microswitch
Section; "E15"