Henny Penny OEA/OGA-341 Technical Manual page 30

High volume open fryer
Table of Contents

Advertisement

2-18. HEATING
CONTACTORS
(ELECTRIC)
(Continued)
Replacement
(Heat Contactor)
Figure 2-54
2-20
To avoid electrical shock, make connections before
applying power, take reading, and remove power before
removing meter leads. The following checks are
performed with the wall circuit breaker closed and the
main power switch in the ON position.
1. Re-apply power to unit and turn power switch to ON.
2. Using illustrations from previous page, check voltage as
follows:
Test Points
Heat Contactor
From terminal 34 to 35
From terminal 35 to 36
From terminal 34 to 36
Test Points
Primary Contactor
From terminal 27 to 28
From terminal 28 to 29
From terminal 27 to 29
If neither contactor is defective it must be replaced as follows:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle, to the frypot
to be worked on. Be aware the other control on 2-frypot
units will have power.
1. Remove only the wires directly connected to the contactor
being replaced. Label the wires for replacement. Figure 2-54.
Model OFE/OFG/OEA/OGA-341, 342
Results
The voltage should read
the same at each terminal
It should correspond to the
voltage stated on the data
plate.
1003