Henny Penny OEA/OGA-341 Technical Manual page 8

High volume open fryer
Table of Contents

Advertisement

1-2. TROUBLESHOOTING
(Continued)
PROBLEM
Shortening will not
drain from frypot
Filter motor runs
but pumps shortening
slowly
Filter switch on,
motor does not run
Motor hums but
will not pump
1-4
CAUSE
• Drain valve clogged
with crumbs
• Drain valve will not
open by turning
handle
• Pump clogged
• Filter line connection • Tighten all filter line connections
loose
• Solidified shortening • Clear all filter lines of solidified shortening
in lines
• Defective switch
• Defective motor
• Motor thermal
protector tripped
• Clogged lines or
pump
Model OFE/OFG/OEA/OGA-341, 342
CORRECTION
• Open valve, force cleaning brush through
drain
• Replace cotter pins in valve coupling
• Remove pump cover and clean
• Check/replace switch per Filter Switch
Section
• Check/replace motor
• Reset thermal switch on filter motor
• Remove and clean pump and lines
• Replace pump seal, rotor and rollers
1003