D. Framing
•
Choose an appliance location and frame as shown
below.
•
It is important to allow for nished face when setting the
depth of the frame.
•
The appliance can now be positioned in the opening.
•
Level it with shims if necessary, and attach the unit to the
frame using the nailing anges provided.
C
A
A
Rough Opening
Width
in.
30 1/2
mm
775
SFE-ST Framing Dimensions
17 in.
(432 mm)
SFE-ST Appliance Dimensions
4
B
B
C
Rough Opening
Rough Opening
Height
Depth
26 1/4
17
667
432
30.3 in.
(770 mm)
.5 in.
(13 mm)
26 in.
(660 mm)
18 in.
(457 mm)
Hearth & Home Technologies Inc. • SFE-ST • 4050-510 Rev A • 05/08
E. Hardwire Electrical Connections
WARNING! Electrical wiring must comply with local
building codes and other applicable regulations to
reduce the risk of re, electrical shock and injury.
Note: All wiring must be completed prior to nishing the
unit.
For supply connections use No. 14 AWG or larger wires.
Use copper wire only. Connect only to a 15 AMP branch
circuit.
•
Remove the screws securing the junction block cover.
•
Wire to a properly grounded, 120 volt, 60 Hz, 15 AMP
circuit
•
Ensure all junction block connections are tight.
•
Replace the cover and retaining screws.
•
All components and wiring may be inspected by removing
the top inter-panel through the appliance front opening.
F. Electrical Speci cations
Voltage . . . . . . . . . . . . . . . . . . . . . . 120 V AC, 60 Hz
Total Amps . . . . . . . . . . . . . . . . . . . . . . . . 0.15 AMP
Total Watts . . . . . . . . . . . . . . . . . . . . . . . . . 18 Watts
G. Wall Switch Connections
WARNING! Do NOT connect the optional low voltage
switch to 120 volt branch circuit.
The optional WSK-21 Wall Switch contains a single pole low
voltage switch.
Maximum run distance is 30 ft. (9.14 m) with 20 gauge solid
copper low voltage thermostat wire. Connect the leads from
the switch to the #2 and #3 terminals on the terminal block
located under a cover on the lower side of the inner top.