Hearth and Home Technologies BE-36-C Owner's Manual

Installation and operation
Hide thumbs Also See for BE-36-C:
Table of Contents

Advertisement

Models:
BE-36-C
BE-36-CIPI
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in
these instructions is not followed
exactly, a fi re or explosion may result
causing property damage, personal
injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert children and adults to hazards of high temperatures.
• Do NOT operate with protective barriers open or
removed.
• Keep clothing, furniture, draperies and other
combustibles away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory-trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Hearth and Home Technologies BE-36-C

  • Page 1 CAN/CSA Z240MH. professionals, or technicians supervised by an NFI This appliance is only for use with the type(s) of gas indicated certifi ed professional. on the rating plate. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 2 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 3: Table Of Contents

    E. Contact Information ........66 B. Disassembly of Vent Sections ..... 29 C. Installing Heat Shield and Horizontal Termination Cap ......31 D. Installing Roof Flashing and Vertical Termination Cap .......... 33 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 4: Listing And Code Approvals

    fi bers, plastics, or other material that can ignite and Heat & Glo Quality Systems burn, whether fl ame proofed or not, or whether plastered or registered by SGS ICS unplastered shall be considered combustible materials. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL installation. OBSTRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 6: Getting Started

    Safety glasses Level 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Manometer Voltmeter Tape measure Noncorrosive leak check solution One 1/4 inch female connection (for optional fan). Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 7: Framing And Clearances

    • Vent Clearances and Framing (Section 6). Models Inches 41-1/2 58-3/4 48-1/2 68-1/4 16-1/4 BE-36-C See Section D for BE-36-CIPI Alcove Installation Millimeters 1054 1492 1232 1734 Figure 3.1 Appliance Locations Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 8: Constructing The Appliance Chase

    Combustible to Ceiling Flooring Appliance Appliance Appliance Opening Opening Opening Opening (Height) (Width) Floor (Width) (Width) (Depth) (Depth) BE-36-C 8-5/8 27-1/2 16-1/4 BE-36-CIPI Figure 3.2 Clearances to Combustibles Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 9: Mantel Projections

    2 ” Figure 3.4 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of opening.) Figure 3.3 Clearances to Mantels or other Combustibles above Appliance Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 10: Termination Locations

    20 in. min. Horizontal distance between terminations 20 in. 24 in. min. Distance to perpendicular wall 18 in. 18 in. Vertical distance between terminations Figure 4.3 Multiple Vertical Termination Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 11 Figure 4.4 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 12: Vent Information And Diagrams

    3 to 12 76 to 305 Figure 5.1). DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Figure 5.2 DVP Pipe Effective Length Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 13: Use Of Flex Vent

    1 in. clearance to combustibles. However, CLEARANCE the vent attachment point and the fi restop location are considered to be supports. Figure 5.3 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 14: Vent Diagrams

    NOTE: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.3). Figure 5.5 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 15 H when using fl ex vent except when using the Note: Use SL D- Series simple up and out installation components only. (see Figure 5.3). Figure 5.6 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 16 2-1/4 in. self tapping screws provided. components only. VIEW FROM UNDERNEATH BAFFLE FRONT OF UNIT FIREBOX BACK SIDE VIEW EXHAUST BAFFLE FIREBOX BACK Figure 5.8 Figure 5.7 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 17 14 ft. 4.3 m 14 ft. 4.3 m MAX. =14 FT (4.3 m) MAX. = 40 FT (12.2 m) Note: Use SL D- Series components only. Figure 5.10 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 18 Note: Use DVP Series components only. Figure 5.11 Rear Vent - Horizontal Termination = 9 in. (229 mm) Maximum One 45º Elbow Note: Use DVP Series components only. Figure 5.12 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 19 3 ft. 1.1 m 7-1/2 ft. 2.3 m 14 ft. 4.3 m components only. MAX. =14 FT (4.3 m) MAX. = 40 FT (12.2 m) INSTALLED HORIZONTALLY Figure 5.14 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 20 1.4 m 3 ft. 1.1 m 6-1/2 ft. Note: Use DVP Series MAX. =6-1/2 FT (2.0 m) components only. MAX. = 40 FT (12.2 m) INSTALLED HORIZONTALLY Figure 5.16 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 21 1.1 m 7-1/2 ft. 2.3 m 14 ft. 4.3 m MAX. =7-1/2 FT (2.3 m) MAX. =14 FT (4.3 m) MAX. = 40 FT (12.2 m) Figure 5.17 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 22: Vent Clearances And Framing

    1 in. CLEARANCE WALL BOTTOM & SIDES SHIELD FIRESTOP WALL Figure 6.2 Horizontal Venting Clearances to Combustible Materials Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 23: Vertical Penetration Framing

    • Field construct additional shield height if insulation is deeper than height of attic ATTIC SHIELD INSTALLED ATTIC SHIELD INSTALLED shield. ABOVE CEILING BELOW CEILING Figure 6.5 Installing the Attic Shield Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 24: Appliance Preparation

    For rear venting there is no insulation in the outer Figure 7.3 Remove the white gasket material covering vent pipe. Replace the top heat shield. the seal cap. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 25: Rear Vent

    Figure 7.7 Cut the metal retaining band and fold the sides place). Slide the insulation gasket onto the vent section, out. up against the appliance and over the tabs. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 26: Securing And Leveling The Appliance

    • Do NOT notch into the framing around the appliance spacers. Failure to keep insulation, framing or other material away from the appliance may cause fi re. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 27: Installing Vent Pipe

    fl ue at the horizontal elbow joint to prevent the elbow from ro- tating. Use screws no longer than 1 inch. If predrilling screw holes, do NOT penetrate inner pipe. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 28 If the slip section is too long, the inner and outer fl ues of the slip section can be cut to the desired length. Figure 8.7 Screws into Slip Section Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 29: Disassembly Of Vent Sections

    • Do NOT allow vent to sag below connection point to appliance. Improper support may allow vent to sag or separate. Figure 8.11 Align and Disassemble Vent Sections Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 30 • Maintain specifi ed slope (if required). preceding component, attach with a minimum of two (2) Improper support may allow vent to sag or separate. sheet metal screws. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 31: Installing Heat Shield And Horizontal Termination Cap

    When penetrating a brick wall, a brick extension kit is available the top of the vent (pipe section) to properly space it from for framing the brick. the pipe section (see Figure 8.12). Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 32 HEAT SHIELD TRIM HEAT SHIELD IF TOO LONG, ADD TO SHIELD IF TOO SHORT WALL SHIELD FIRESTOP (EXTERIOR) WALLSHIELD FIRESTOP (INTERIOR) Figure 8.15 Heat Shield, Interior & Exterior Firestops Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 33: Installing Roof Flashing And Vertical Termination Cap

    Inspect external vent cap regularly. • Ensure no debris blocks cap. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Figure 8.18 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 34 Slide the assembled storm collar down the pipe section until it rests on the roof fl ashing. Caulk around the top of the storm collar (see Figure 8.17). Figure 8.19 Assembling the Storm Collar Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 35: Gas Information

    Propane Minimum 5.0 inches 11.0 inches Inlet Pressure w.c. w.c. Maximum Inlet 14.0 inches 14.0 inches Gas Pressure w.c. w.c. Manifold 3.5 inches 10.0 inches Pressure w.c. w.c. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 36 Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 37: Electrical Information

    National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1. PILOT THERMOPILE THERMOCOUPLE PIEZO THERMOSTAT WIRE ASSEMBLY VALVE Figure 10.2 Standing Pilot Ignition Wiring Diagram Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 38: Standing Pilot Ignition System Wiring

    TRANSFORMER WHITE 3 VAC ORANGE GROUND TO FIREPLACE PLUG IN CHASSIS JUMPER WIRE BATTERY PACK (TO BROWN) THERMOSTAT WIRE ASSEMBLY VALVE Figure 10.3 Intellifi re Ignition Wiring Diagram Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 39: Junction Box Installation

    Figure 10.5 Junction Box Wired to Wall Switch connector (1/4 inch male) as shown. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 40: Finishing

    Seal joints between the fi nished wall and appliance top • Operation of louvers or doors. and sides using only a 300º F minimum sealant. • Access for service. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 41: Appliance Setup

    Do NOT place on burner top. • Save the remaining ember materials for use during appli- ance servicing. The embers provided should be enough for 3 to 5 applications. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 42: Positioning The Logs

    fi rebox while the rear lines up with the left log. The left edge of log #3 should rest on the grate and log #1 as shown. 397-935B 6/04 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 43: Glass Assembly

    Replace the glass door on the appliance. Pull out and latch the four glass assembly latches into the groove on the glass frame. LATCHES (BOTH BOTTOM AND TOP) GLASS ASSEMBLY Figure 12.2 Glass Assembly Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 44: Operating Instructions

    • Glass door MUST be in place and sealed before operating appliance. • Only use glass door certifi ed for use with appliance. • Glass replacement should be done by qualifi ed technician. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 45: Lighting Appliance

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 46: Standing Pilot Ignition

    For additional information on operating your wise to OFF”. Do not force. Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. 5. Close control access panel. 464-903G Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 47: After Appliance Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when ON/OFF is turned off. In a standing pilot system the pilot will always stay on. continually? Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 48: A. Standing Pilot Ignition System

    Take a reading at the thermopile leads. The read- ing should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 49: Standing Pilot Ignition System

    Ensure that the glass is tightened properly on the unit, particularly on top corners. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 50: Intellifi Re Ignition System

    fl ame lifts from pilot hood, the circuit is broken. A wrong orifi ce or too high an inlet pressure can cause pilot fl ame to lift. The sensor rod may be contaminated. Clean sensor rod with emery cloth. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 51 Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batter- solenoid ohms readings. ies if voltage is below 2.7. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 52: Maintaining And Servicing Appliance

    • Restricted air fl ow affects burner operation. • Air passageways, grilles, control compartment • Burner, burner ports Risk of: • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 53 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 54: Reference Materials

    ELECTRICAL ACCESS Location Inches Millimeters Location Inches Millimeters 8-3/4 16-1/4 32-1/2 27-3/8 25-3/4 18-1/2 12-7/8 15-7/8 3-1/2 6-5/8 6-7/8 23-3/8 2-3/8 32-1/2 36-1/2 30-1/8 Figure 16.1 Appliance Dimensions Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 55: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 56 (305 mm) Length 6-3/4 in. 10-5/8 in. DVP-TRAP Trap2 171 mm 270 mm Horizontal Termination Cap DVP-TRAP1 DVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 DVP-HPC1 DVP-HPCK1-B DVP-HPC2 DVP-HPCK2-B Figure 16.3 DVP vent components Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 57 5-3/4 in. (146 mm) COOL-ADD Cap Shield 13-7/8 in. 9-1/2 in. (352 mm) (241 mm) 14 in. (356 mm) DVP-TRAPFL Flashing DRC-RADIUS Cap Shield Figure 16.4 DVP vent components Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 58 (222 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) 1-5/8 in. (41 mm) DVP-FBHT Fire Brick Termination Cap DVP-HPC High Performance Cap Figure 16.5 DVP vent components Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 59 There must be a 25% reduction in total H when using the snorkel cap except when using the simple up and out installation. WALL BRACKET (SL- SERIES) SL Series Vent Components Figure 16.6 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 60: Service Parts

    BE-36-C C. Service Parts Beginning Manufacturing Date: 4-01 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 61 LPK-BE36-CIPI Conversion Kit LP Regulator NG NGK-DXF LPK-DXF Regulator LP Pilot Spud NG 446-505 Pilot Spud LP 446-517 Additional service part numbers may appear on the following page. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 62 2025-101 Valve Bracket Post 0021076020 2025-101/2044-155 Valve Plate Gasket 530-431 530-302A Flexible Gas Connector Piezo Ignitor 291-513 Flex Tube Assembly 530-302A Pre 0021076020 530-164 Pilot Bracket Post 0021076020 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 63 3 Volt Transformer Flex Tube Assembly 530-302A Pre 0021076020 385-512 Ground Strap Post 0021076020 Pre 0021076020 530-164 Pilot Bracket Post 0021076020 Pre 0021076020 397-121 Pilot Assembly Support Post 0021076020 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 64: Limited Lifetime Warranty

    Product. HEARTH & HOME TECHNOLOGIES also reserves the right to discontinue styles and products. © 2005 Hearth & Home Technologies Inc. Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...
  • Page 65: Contact Information

    6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2006 Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. V 1/07...

This manual is also suitable for:

Be-36-cipi

Table of Contents