6. Install the reservoir insulation, tube clamp, and
solenoid lever with three screws.
7.
Install solenoid.
1. Remove and inspect O ring seal. Replace if
damaged in any way (Fig. 25.1).
2. Clean O ring groove. Lubricate O ring with petrol-gel
and reinstall (Fig. 25.2).
3. Use cardboard disc to press new mating ring into
main housing (Fig. 26.1).
4. Lube the shaft with liquid soap in the area shown
(Fig. 26.2) and slip on seal and spring (Fig. 26.3).
Note: Do not touch the sealing surfaces with bare
hands. Contact with bare skin will cause
premature seal failure.
5. Install auger (Fig. 26.4).