Dimensions and clearances

Entire front of ice machine must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above ice machine for service.
1" (26mm) minimum clearance on sides.
The intake and exhaust air grilles must provide at least 150 sq in (968 sq cm) of open area.
Air-cooled model ice machines – 18" (458mm) minimum clearance between discharge and air intake-grilles.
• Keep ventilation openings in the appliance enclosure or built-in structure, clear of obstruction
Front View
Air intake
CAUTION
Side View
21.28" (541mm)
23.50"
(597mm)
Easton Pennsylvania
CORPORATION
MODEL
SERIAL NO
PART NO
FULL LOAD AMPS
VOLTS
HZ
SINGLE
PHASE
MOTOR COMPRESSOR THERMALLY PROTECTED
REFRIGERANT
CHARGE
OZ
DESIGN PRESSURE HIGH SIDE
LOW SIDE
PSIG
208264
Stock Module Identification Plate
MIN. BRANCH CIRCUIT AMPACITY
AMPS
U L
U L
Module No.
NSF
MADE IN
THE USA
MAX. BRANCH CIRCUIT FUSE SIZE
AMPS
R
R
Product
C
Service No.
21.05" (535mm)
23.77" (604mm)
6
Ice transport hose connection
Air exhaust
both sides
Cord only
15.56"
(396mm)
6.95"
(177mm)
2.53"
(65mm)
1/4" FPT condensor drain
(water-cooled only)
1/4" FPT condensor inlet
(water-cooled only)
Back View
Air exhaust
29.63" (753mm)
2.43" (62mm)
3/8" OD push-in water inlet
3/4" MPT drain