Rx Input Verification Test; Storage And Reshipment - Radyne OM20 Installation And Operation Manual

Universal outdoor modem
Hide thumbs Also See for OM20:
Table of Contents

Advertisement

OM20 Universal Outdoor Modem

3.3.2 RX Input Verification Test

Connect a Spectrum Analyzer and Bias-T to the RXRF L-Band Output of the LNB. Ensure that
the Antenna is correctly tuned and that the carrier of interest is visible and that the frequency and
power level is correct. Verify that all the receive parameters of the OM20 are correct. Remove
the LNB coax cable from the Bias-T and connect to the RX L-Band input port J7 on the OM20.
Enable the correct DC Bias Voltage for the LNB from the OM20 Browser. Verify that the OM20
receiver locks to the carrier of interest.
DC Voltage may be present on the output connector.
3.4

Storage and Reshipment

It is recommended that the unit be stored or reshipped in its original sealed packing. The unit
should be stored in a dry location where the temperature is stable, away from direct contact with
rain, snow, wind, sun, or anything that may cause damage.
MN-OM20– Revision 5
CAUTION
OM20 Initial Configuration
3–5

Advertisement

Table of Contents
loading

Table of Contents