OM20 Universal Outdoor Modem
AUPC MODE
Allows the user to enable or disable the AUPC Function of the remote modem. The remote AUPC Function is the
response of the local modem to commands for an increase or decrease of the Transmit Power in 0.5 dB steps and the command to change to
the setting indicated in the 'REMOTE CL ACTION' Menu of the remote modem upon receiver loss of lock.
LOOPBACK
TX 2047 TEST
RX 2047 BER:
When modems are configured for Radyne AUPC, the remote Eb/No will be
displayed in the Monitor Menus.
MN-OM20– Revision 5
{DISABLE,NEAR SIDE, EFDATA}
{DISABLE, ENABLE}
Allows the user to enable or disable the Baseband Loopback Test
Mode of the remote modem.
{DISABLE, ENABLE}
Allows the user to enable or disable the Transmit 2047 Pattern
Test Mode of the remote modem.
Reports the BER measurement of the receiver 2047 Pattern Test
Mode of the remote modem. BER is reported from the 1x10
-7
1x10
in tenth decade steps.
if the pattern does not synchronize or is out of range, 'NO
DATA' will be displayed.
IMPORTANT
Web Browser/Remote Protocol
-5
to
6–28