Link Up Cable Of Nm Interface - Raisecom RCMS2504-120 User Manual

Rcms2504-120 series standalone, fiber optic ethernet multiplexer
Table of Contents

Advertisement

others ——
Line orders between RS232 (RJ45) and PC serial port (DB9 female connector) are as following:
A.4 LINK UP cable of NM interface
Connect LINK UP interface with console interface
LINK UP interface adapts RJ45 whose pins definition are as following,
RS232 Part:
3
——RXD
7
——TXD
4¡ ¢ 8——GND
RS485 Part,
1
——RXD+
2
——RXD-
5
——TXD-
6
——TXD+
NOTE: output and input of signal is as far as equipment itself.
Unassigned
RJ45
3
6
4¡ ¢ 5
232signal input
232 signal output
485 signal input
485 signal input
485 signal output
485 signal output
DB9F
←—
3
—→
2
——
5
17
Raisecom Technology Co., Ltd

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rcms2504-120bRcms2404-240

Table of Contents