4. MENU SETUP

4. MENU SETUP
6
There are
categories for operation setting in the
setup menu system as shown below. The following
sections will instruct you step by step to configure
the operation setting and state each menu's
purpose and options. Press the Setup button
to access the setup menu. Once inside the menu
system, the on-screen menu allows you to set up
the key features of the unit. The functions of
various buttons within the menu-setup mode are
described in the paragraphs below.
KEY FUNCTIONS
Setup button
9
:
Press to enter the setup menu. Press again to
exit the setup mode.
^
"
"
12
and "v"
13
buttons :
Press to select the desired item or entry for
setting.
11
14
"<"
and ">"
buttons :
Press to highlight the desired option or to select
the context for setting.
15
Enter
button :
Press to enter the selected item and to save the
setting.
Shuttle Ring
20
:
Turn to highlight the desired option or to select
the context for setting.
Jog Dial
21
:
Turn to select the desired item or entry for
setting.

4.1 REC Setting

MAIN MENU
RECORD
ALARM/ MOTION
CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM
9
GOTO REC PAGE
This page allows you to set the recording rate
and recording quality, and enables you to
continue recording when the disk is full.
MAIN MENU
RECORD
ALARM/ MOTION
CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM
GOTO REC PAGE
REC RATE
REC QUALITY
DISK FULL
AUDIO
MULTIPLEXER
MAIN PAGE
REC RATE :
This option is for adjusting the number of
pictures recorded every second into a storage
disk. The recording rate controls the frequency
at which the number of video pictures can be
recorded.
For an NTSC unit there are 11 different
recording rates you can select from: 60F/S (60
fields per second ), 30F/S, 20F/S, 12F/S,
5.5F/S, 2.4F/S, 1.22F/S, 0.71F/S, 1 F/4S,
1F/6S, and 1F/8S.
For a PAL unit there are 11 different recording
rates you can select from: 50F/S (50 fields per
second), 25F/S, 17F/S, 10F/S, 5.5F/S, 2.9F/S,
1.52F/S, 0.88F/S, 1 F/4S, 1F/6S, and 1F/8S.
29
REC SETTING
: 20 F/S
: BEST
: REWRITE
: OFF
: ON