Section 7: Appliance Set-Up; Leveling System; Outside Air Kit - Quadra-Fire Santa Fe Pellet Insert SANTAFEI-B Owner's Manual

Santa fe pellet insert installation and operation
Table of Contents

Advertisement

R
7
Appliance Set-Up
A. Leveling System
The leveling bolts are located at the rear of the appliance.
To access the bolts, remove the front access panels. Reach
in and turn the bolt to the desired height to level the appli-
ance.
Leveling Bolt on Each Side
Figure 17.1
September 1, 2008
Figure 17.2
Air Intake Channel
Hose Clamp
Collar
Assembly
B. Outside Air Kit Instructions
Parts Included in Kit: 1 piece of 2 inch x 3 ft. flex hose,
2 hose clamps, 1 collar assembly, 1 termination cap
assembly, 1 trim ring, fasteners.
Tools Needed: Phillips head screwdriver; wire cutters;
hole saw or jig saw.
1. Measure distance from floor to air vent opening in appli-
ance and mark location on wall.
2. Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.
3. Use hose clamp to secure flex pipe to collar assembly.
4. Slide trim ring over flex pipe and run pipe through wall.
5. Attach hose to outside termination cap with second
hose clamp.
6. Secure termination cap to outside surface.
7. Secure trim ring to interior wall.
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Trim Ring
Flex Hose
7019-205C
Santa Fe Pellet Insert
CAUTION
Termination
Cap Assembly
Hose Clamp
Page 17