Travis Industries DVS EF Fireplace Owner's Manual page 40

Built-in direct vent fireplace
Table of Contents

Advertisement

Optional Equipment
4 0
4
Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice
(.0625 dia. - it has ".0625" stamped on it) and tighten in place with a 1/2" open end wrench. Replace
the spring. Slide the adjustable shutter back in place.
Use a 1/2" open end wrench to
unscrew the burner orifice.
5/16"
5
Replace the burner pan and ember shelf.
6
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice.
Lift the pilot hood
a
off the pilot
assembly.
7
Replace the pilot assembly (follow the instructions in step 6 in reverse order). Make sure the pilot
assembly gasket is placed correctly.
8
Install the logs and embers. Replace the glass.
© Travis Industries
1/2" Wrench
NOTE:
Screw the LP orifice in
so the orifice shoulder
protrudes 5/16"
(indicating full insertion).
Remove the orifice and replace with the LP orifice. Screw the
c
orifice all the way in and replace the pilot hood.
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
4041213
(for qualified installers only)
The new LP orifice
has ".0625"
stamped on it.
Apply thread
sealant to the
new orifice and
install.
The old NG
orifice has "37"
stamped on it.
Orifice Identification:
35
LP (Propane) Orifice
35
NG (Natural Gas) Orifice
62
1 0 0 - 0 1 1 5 2