Device Overview
(5) Current Requirements and Power Dissipation
Table 1.3 lists the current and power dissipation (typical).
Spin up (*1)
Idle
R/W (on track) (*2)
Seek (*5)
Standby
Sleep
Energy
Efficiency (*4)
*1
Maximum current at starting spindle motor.
*2
Current and power level when the operation (command) that accompanies a
transfer of 63 sectors is executed 3 times in 100 ms
*3
Power requirements reflect typical values for +5 V power.
*4
Energy efficiency based on the Law concerning the Rational Use of Energy
indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)
*5
The seek average current is specified based on three operations per 100
msec.
1-8
Table 1.3 Current and power dissipation
Typical RMS Current
0.9 A
100 mA
320 mA
380 mA
40 mA
20 mA
—
Typical Power (*3)
4.5 W
0.50 W
1.6 W
1.9 W
0.20 W
0.1 W
0.0063 W/GB (rank D / MHW2080AT)
0.0083 W/GB (rank D / MHW2060AT)
0.0125 W/GB (rank D / MHW2040AT)
C141-E250