Table 1.3 lists the current and power dissipation (typical).
SATA interface
Gen1 (1.5 Gbps) Gen2 (3.0 Gbps)
transfer speed
Spin up (*1)
Idle (*6)
R/W (on track) (*2)
Seek (*5)
Standby (*6)
Sleep (*6)
Energy
Efficiency (*4)
*1
Maximum current and power at starting spindle motor.
*2
Current and power level when the operation (command) that accompanies a
transfer of 63 sectors is executed 3 times in 100 ms
*3
Power requirements reflect typical values for +5 V power.
*4
Energy efficiency based on the Law concerning the Rational Use of Energy
indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)
*5
The seek average current is specified based on three operations per 100
msec.
*6
IPM mode: Slumber mode.
1-8

Table 1.3 Current and power dissipation

Typical RMS Current
1.1 A
1.1 A
160 mA
160 mA
420 mA
460 mA
460 mA
500 mA
26 mA
26 mA
26 mA
26 mA
Typical Power (*3)
Gen1 (1.5 Gbps)
Gen2 (3.0 Gbps)
5.5 W
0.80 W
2.1 W
2.3 W
0.13 W
0.13 W
e rank (0.0067 W/GB): MHW2120BK
e rank (0.0100 W/GB): MHW2080BK
d rank (0.0133 W/GB): MHW2060BK
5.5 W
0.80 W
2.3 W
2.5 W
0.13 W
0.13 W