Side Refl Ector Panel Installation - Heat & Glo Cyclone-BC Owner's Manual

Hearth & home technologies gas fireplace owner's manual installation and operation manual
Table of Contents

Advertisement

Figure 14.2 The glass platform plate can now be removed by
removing the 10 screws on the outer edge of this platform.
Figure 14.3 Lift the platform. The HSI (Hot Surface Ignitor)
and the sensor wire can be unplugged. Set platform aside.
Figure 14.4 Remove the tube burner. It is held in place with
one screw. Pull the burner tube away from orifi ce holder,
rotating burner tube slightly, and remove it from the orifi ce.
Heat & Glo • Cyclone-BN, Cyclone-BC • 2073-900 Rev. N • 10/08
Figure 14.5 The fan plate can now be accessed. Remove
the four screws. Lift the fan plate, being careful to not cut or
scar wiring while disconnecting them from the fan motor.
B. Side Refl ector Panel Installation
To install the refl ector panels, insert the panel by aligning
the teeth on the panel with the slots in the back of the
appliance.
TEETH
SLOT
TEETH
Figure 14.6
When screwing the panel in place start with
the center screw and with your free hand lift the panel up
so that it comes in contact with the top refl ector panel.
Insert all screws until fi nished.