Table of Contents

Advertisement

CAUTION! Risk of Fire! DO NOT store instruction manuals inside fi replace cavity.
High temperatures could cause a fi re.
INSTALLER: Leave this manual with the appliance, not inside the appliance.
CONSUMER: Retain this manual for future reference. Do not store inside the appliance.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
Decorative barrier front must be ordered separately at
time of appliance purchase. See Section 3.A.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo COSMO32-IFT-B

  • Page 1 Decorative barrier front must be ordered separately at time of appliance purchase. See Section 3.A. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 2: Table Of Contents

    D. Non-Combustible Material Installation ....43  = Contains updated information. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) = Contains updated information. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 4: Product Specifi C And Important Safety Information

    Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 5: Non-Combustible Materials Specifi Cation

    State of California to cause cancer and reproductive harm. For more information go to: www. P65Warnings.ca.gov. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 7: Getting Started

    Use appropriate fi nishing materials that are able to withstand these conditions. For additional fi nishing guidelines, see Section 10. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 8: Tools And Supplies Needed

    • Improper positioning of the logs/media (as applicable) or the glass assembly. • Installation and/or use of any component part not approved by Hearth & Home Technologies. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 9: Framing And Clearances

    6-5/8 27-1/4 34-3/8 15-1/4 2-3/16 38-1/16 3-1/2 17-1/4 25-7/8 40-1/2 1029 38-1/2 9-13/16 6-1/8 17-3/4 7-1/2 10-3/8 25-3/4 7-3/4 Figure 3.1 Appliance Dimensions - COSMO32-IFT-B Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 10 32-1/4 32-3/8 15-1/4 2-3/16 33-11/16 3-1/2 17-1/4 25-7/8 46-1/2 1181 43-1/2 1105 9-13/16 6-1/8 17-3/4 7-1/2 10-3/8 30-3/4 7-3/4 Figure 3.2 Appliance Dimensions - COSMO36-IFT-B Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 11 32-3/8 39-1/16 15-1/4 2-3/16 33-11/16 3-1/2 17-1/4 25-7/8 50-1/2 1283 46-1/2 1181 6-1/8 9-13/16 7-1/2 17-3/4 10-3/8 7-3/4 37-3/4 Figure 3.3 Appliance Dimensions - COSMO42-IFT-B Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 12 19-7/8 26-7/8 25-3/16 COSMO36-IFT-B CFTF-36 40-3/16 14-1/8 45-1/8 6-7/8 9-13/16 19-7/8 26-7/8 25-3/16 COSMO42-IFT-B CFTF-42 1021 1146 Figure 3.4 Decorative Barrier Front Dimensions - CFTF Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 13 20-3/4 27-1/16 25-15/16 COSMO36-IFT-B MAR-COSMO36 40-1/4 14-7/8 46-3/16 6-5/16 9-5/16 20-3/4 27-1/16 25-15/16 COSMO42-IFT-B MAR-COSMO42 1023 1172 Figure 3.5 Decorative Barrier Front Dimensions - MARTINI Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 14: Appliance Location And Clearances To Combustibles

    See Section 10.C for Alcove Installation COSMO36-IFT-B (Mantel and Wall Projection). Millimeters 1207 1067 1676 Inches 50-1/2 71-1/2 19-1/2 17-1/4 COSMO42-IFT-B Millimeters 1283 1245 1816 Figure 3.6 Appliance Locations Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 15 ** If appliance is installed off of fl oor, maintain required clearances to combustibles. Construct platform in accordance with local building codes. Figure 3.7 Clearances to Combustibles Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 16 ** Measurement without Trim Kit = 2 in. + Additional Finishing Material Thickness. If fi nished discharge opening height is greater than 3 inches, wire mesh is required. Figure 3.8 Passive Heat Front Discharge Framing Dimensions With and Without a Trim Kit Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 17 36-1/2 5-5/8 38-3/8 PHTRIM-36LINEAR millimeters Inches 2-9/16 48-1/2 5-5/8 50-3/8 PHTRIM-42LINEAR millimeters 1232 1280  Figure 3.9 Passive Heat Front Discharge - Vent Cover Dimensions Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 18 Appliance to Ceiling Bottom of Appliance Materials COSMO32-IFT-B Inches 12-1/4 8-3/4 63-5/8 77-3/8 COSMO36-IFT-B COSMO42-IFT-B millimeters 1616 1965 Figure 3.10 Passive Heat Side Discharge Framing Dimensions Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 19 Mesh screen required for front discharge or open top discharge passive heat installations with discharge opening of 3 inches or greater. Figure 3.11 Passive Heat Minimum Framing Dimensions Open Top Discharge Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 20: Constructing The Appliance Chase

    Minimum height requirements for an exterior chase on a top- vented appliance are shown in Figure 3.12. Reference Fig- ure 4.5 for additional clearances. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 21: Termination Location And Vent Information

    WARNING! Risk of Fire or Asphyxiation. This appli- ance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 22 Measure horizontal and vertical termination cap clearances as noted in Figure 4.3 and Figure 4.4. H=Measure Horizontal Distances from H V=Measure Vertical Distances from V Figure 4.3 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 23: Vent Terminal Clearances

    12 in. (305 mm)* two sides beneath the fl oor.) vinyl or composite overhang 42 in. (1067 mm) 42 in. (1067 mm) Figure 4.5 Minimum Clearances for Termination Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 24: Use Of Elbows

    Figure 4.7 Vertical and Horizontal Off set for DVP and SLP Elbows SLP48 1219 SLP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 SLP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.6 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 25: Use Of Flex Vent (Slp-Flex Series 6-5/8 Inch)

    Figure 4.8 Measure to Outside Mounting Surface Figure 4.10 Flex Vent Pipe - Generic Fireplace Shown Figure 4.9 Measure to Top of Last Section of Pipe Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 26: Vent Diagrams

    • Horizontal termination cap should have a 1/4 inch downward slant to allow any moisture in cap to be released. See Figure 4.11. Figure 4.11 Vent Cap Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 27 (6-5/8 inch) vent except when using glass breakage. the simple up and out installation. See Figure 4.10. Note: Use SLP Series components only. Figure 4.12 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 28 CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. INSTALLED HORIZONTALLY Figure 4.13 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 29 CAUTION: The SLP-HRC-SS termination caps are not approved for use with these models. May lead to elevated glass temperature that may cause tempered glass breakage. Figure 4.14 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 30 1.2 m 15 ft. 4.6 m glass breakage. MAX. = 15 ft. (4.6 m) MAX. = 7 ft (2.1 m) INSTALLED HORIZONTALLY INSTALLED HORIZONTALLY Figure 4.15 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 31 Note: Use SLP Series components only. Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed. Figure 4.16 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 32 Step 1. EXHAUST RESTRICTOR INSTALLED SCREWS Figure 4.17 Installing Restrictor Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 33 H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.10. Note: Use SLP Series components only. Figure 4.18 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 34 Note: There MUST be a 25% reduction in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.10. Figure 4.19 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 35 Maximum= 40 ft. (12.2 m) in total H when using SLP-FLEX Series (6-5/8 inch) vent except when using the simple up and out installation. See Figure 4.10. Figure 4.20 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 36 • Aluminum material degradation could cause fl ex vent system to fail. • Installer MUST install the 3 ft. stainless steel fl ex on COSMO32-IFT-B. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 37 To minimize cold air APPLIANCE CONNECTOR drafts, seal with non-combustible insulation. DIRECT VENT FIREPLACE HEARTH FLOOR Minimum 10 ft 3.05 m Maximum 40 ft 12.2 m Figure 4.23 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 38: Vent Clearances And Vent Framing

    Note: Center of the horizontal vent pipe to the vertical measuring surface of a trap cap is 5 inches (127 mm) Figure 5.2 Wall Penetration Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 39: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 40: Appliance Preparation

    TOP HEAT SHIELD IN POSITION Figure 6.2 COSMO42-IFT-B B / COSMO36-IFT-B Figure 6.4 COSMO32-IFT-B - Shipping Support and Seal Cap - Top Heat Shield in Position Removed Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 41: Prepare For Heat Management

    -GAS. The dedicated knockouts, as ® shown in Figure 6.5, must be used only as indicated. Passive Heat cannot be used with the Smart-Wall TV Kit or optional fan. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 42: Securing And Leveling The Appliance

    This board must be used. Do NOT remove. See Figure 6.6. FACTORY-INSTALLED NON-COMBUSTIBLE BOARD DO NOT REMOVE NAILING TABS BOTH SIDES Figure 6.6 Proper Positioning, Leveling And Securing Of Appliance Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 43: Non-Combustible Material Installation

    Refer to Section SCREWS INTO 10 for more information. THESE PILOT HOLES NOTE: BOTH LEFT & RIGHT SIDES Figure 6.8 Installation of the Side Non-Combustible Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 44: Venting

    • Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed in this manner, unless otherwise stated. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 45: Assemble Slip Sections

    NOTICE: If slip section is too long, the inner and outer fl ues of the slip section can be cut to the desired length. Figure 7.6 Securing Horizontal Pipe Sections Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 46: Disassemble Vent Sections

    Figure 7.8. • Pull carefully to separate the pieces of pipe. Figure 7.7 Rotate Seams for Disassembly Figure 7.8 Align and Disassemble Vent Sections Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 47: Vertical Termination Requirements

    Slide the storm collar onto the exposed pipe section SEAL and align brackets. • Insert a bolt (provided) through the brackets and install nut. Do not completely tighten. Figure 7.11 Figure 7.11 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 48: Horizontal Termination Requirements

    Important Notice: Heat shields may not be fi eld constructed. VENT DEPTH FROM BACK OF APPLIANCE TO OUTSIDE SURFACE OF EXTERIOR WALL (SEE CHART BELOW) Figure 7.12 Venting Through the Wall Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 49: Electrical Information

    Section 9.B. Figure 8.3 Junction Box Detail - COSMO32-IFT-B NOTE: Appliance shown without glass installed. BOTTOM PANEL SCREW LOCATIONS Figure 8.1 Remove Lower Access Panel Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 50: Wiring Requirements

    Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 51 JUMPER 2187-198 ORANGE DETAIL A GROUND TO FIREPLACE CHASSIS GREEN WHITE WIRE ASSEMBLY 2118-170 BATTERY PACK Figure 8.5 Intellifi re Touch Wiring Diagram - Standard Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 52 6V DC WALL SWITCH BATTERY PACK 2326-134 LED-LINEAR Components shown in diagram. Figure 8.6 Intellifi re Touch Wiring Diagram with Remote, Fan and LED Options Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 53 ORANGE PVI-WH80 PVI-WH100 GROUND TO FIREPLACE CHASSIS OPTIONAL POWER VENT GREEN PVV-SLP PVI-SLP-B PVLP-SLP Figure 8.7 Intellifi re Touch Wiring Diagram with Power Vent Diagram Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 54 (1/4 inch male) as shown. Figure 8.8 Junction Box Wired to Wall Switch Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 55: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. Figure 9.1 Basepan Removal - COSMO42-IFT-B Shown • If substituting for these components, please consult local codes for compliance. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 56 fi nishing material installation. Remove glass assembly and utilize an appropriate sized screwdriver. REMOVE BURNER SCREW Figure 9.2 Burner Removal Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 57: Gas Connection

    DO NOT use open fl ame. Fittings and connections could have loos- ened during shipping and handling. Figure 9.4 Incoming Gas Line Location Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 58: Air Shutter Setting

    fi rebox. If fl ames are dark orange with dark, smoky tips, provide more primary air to the burner by opening the air shutter accordingly. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 59: Finishing

    If the framing thickness is less than 1-1/2 in. nominal, such as Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 60: Non-Combustible Board And Drywall Installation

    In addition to using multiple pieces of decorative fi nish material, the installation of the Passive Heat optional heat management system will also reduce the chances of cracking. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 61 Note: It is acceptable to use a silicone sealant with a minimum of 300 ºF continuous exposure rating to adhere drywall to lower cover panel. Figure 10.2 Finishing Details Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 62: Mantel And Wall Projections

    Figure 10.4 Minimum Vertical and Maximum Horizontal Figure 10.7 Combustible and Non-Combustible Mantel Leg or Dimensions of Combustibles Wall Projections (Acceptable on both sides of opening) Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 63 SIDE DISCHARGE (DISCHARGE SLOTS ON BOTH SIDES OF APPLIANCE) 8-3/4 IN. 12-1/4 IN. Figure 10.8 Finishing Material installed with Passive Heat Optional Heat Management System Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 64 Finishing materials 1 inch maximum thick. Stop fi nishing material fl ush with opening. Figure 10.9 Overlap Fit Decorative Barrier Front (CFTF and Martini Decorative Barrier Fronts) Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 65 Figure 10.11 Maximum Finish Material Thickness - CFTF INNER DECORATIVE FRONT ASSEMBLY Decorative Barrier Front TOP VANITY PANEL (NOT SHOWN) Figure 10.13 CFTF Front Installation With Outer Decorative Barrier Front Trim Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 66 0 IN. (CFTF) Figure 10.14 Clearances to Appliance Opening Without Outer Decorative Front Trim (BOTH SIDES) (BOTH SIDES) Figure 10.15 CFTF Front Without Outer Decorative Front Trim Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 67 NOTE: The TV installation requirements are the same regardless of whether the Passive Heat kit is installed with a top discharge, side discharge or open top discharge.  Figure 10.16 Good Faith Guidelines for TV Installations Above a Fireplace with Passive Heat Option Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 68: Appliance Setup

    Optional log sets are available for use with the COSMO42- IFT-B, COSMO36-IFT-B and COSMO32-IFT-B models. Install the log set per instructions included with the kit. Figure 11.1 Media Placement Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 69: Intellifire Touch Control System Setup

    If the glass frame assembly does not pull back towards the face of the appliance, repeat steps 1-4. Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 70: Install Decorative Barrier Front

    For more information refer to the instructions supplied with your decorative barrier front. LOWER SPRING LATCH Figure 11.3 Fixed Glass Assembly Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 71: Reference Materials

    12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 12.1 SLP Series Vent Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 72 (321 mm) DVP-HSM-B Extended Heat Shield 12-5/8 IN. 10-5/8 IN. (321 mm) (270 mm) SLP-RDS ROOF DECK INSULATION SHIELD Figure 12.2 SLP Series Vent Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 73 343 mm 121 mm 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT SLK-SNKD Horizontal Snorkel Termination Cap Termination Cap Figure 12.3 SLP Series Vent Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 74 Figure 12.4 SLP series Vent Components COAXIAL to COLINEAR VENTING LINK-DV30B 768-380A DV-46DVA-GCL Flex Liner Kit Stainless Steel Flex Pipe Coaxial/Colinear Appliance Connector Figure 12.5 Coaxial to Colinear Vent Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 75 Only use listed decorative termination caps/shrouds with Hearth & Home Technologies approved venting systems. This applies to both DVP and SLP venting systems. Decorative Terminations Caps/Shrouds DTO134 DTO146 DTS134 DTS146 LDS33 LDS46 LDS-BV Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 76 Option A: IFT-RC400 Option B: IFT-RC150 and IFT-ACM. These accessories are purchased separately from the PVV-SLP. Contact your dealer to order. Figure 12.6 PVV-SLP Vent Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 77 424 mm (424 mm) 12-1/2 IN. (318 mm) SLP-LPC SLP Low Profi le Cap (Approved for use with PVI-SLP-B only) Figure 12.7 PVI-SLP-B Vent Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 78 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.8 PVLP-SLP Vent Components Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...
  • Page 79: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2020 Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20...

This manual is also suitable for:

Cosmo36-ift-bCosmo42-ift-b

Table of Contents