C. Firebrick Replacement
The firebox of your fireplace is lined with high quality
firebrick, which has exceptional insulating properties.
There is no need to use a grate; simply build a fire on
the firebox floor. Do not operate the fireplace without
bricks.
IMPORTANT: The bricks are very similar in size. Be
certain you have the proper brick in the correct location.
Measure the brick size for accuracy.
After the coals are completely cooled, remove all
old firebrick and ash from unit and vacuum out
firebox.
1.
Remove new brick set from box and lay out to
diagram as shown in Figure 60.1.
2.
Lay bottom bricks in unit.
3.
Install rear bricks on the top of the bottom bricks.
Slide top of bricks under clip on back of firebox
wall and push bottom of brick back.
4.
Install side bricks. Slide top of brick under clips
on side of firebox and push the bottom of the
brick until it is flush with the side of the unit.
Figure 60.2 Brick Pattern
Page 60
2
1
3
3
4
3
1
3
#
Brick Size
1 13-1/4" x 4-1/2" x 1-1/4"
2 13-1/2" x 4-1/2" x 1-1/4" w/ 1-1/2" chamfer
3 12" x 4-1/2" x 1-1/4"
4 12-1/2" x 4-1/2" x 1-1/4"
Heatilator • Constitution EPA Fireplace • 480-1091C
2
3
3
3
1
Figure 60.1 Brick Pattern
Use Part SRV7000-306 when ordering individual brick.
Provide brick dimension or copy this page, mark the
desired brick and take it to your authorized dealer.
1
2
1
3
4