E. Non-Combustible Facing Material
Installation
WARNING
Risk of Fire.
• Follow these instructions exactly.
• Facing materials must be installed properly
to prevent fire.
• No materials may be substituted
without authorization by Hearth & Home
Technologies.
TOOLS NEEDED: Powered drill with #2 Phillips head bit;
caulking gun.
1. Secure the fireplace to the floor or wall framing studs at
a minimum of two attachment points to prevent further
movement of the fireplace. The same holes and L brack-
ets that attached the fireplace to the pallet may be used
to secure the fireplace to the sub flooring by using a mini-
mum of two 1/4 in. x 2 in. lag bolts or equivalent. Refer
to Figure 42.1 and install the two metal hearth strips at
this time.
NOTE: All boards are pre-drilled for your convenience.
Boards MUST be attached in the following order:
bottom, top, and then the two sides.
2. Attach the bottom board to the bottom of the outer fire-
place can with enclosed screws, ensuring the board is
centered.
3. Center and attach the top board to the outer can and
framing members.
4. Using the Super Calstick, run a light bead (1/8 in. mini-
mum) on the butt edges of the top board. See Figure
42.2.
5. Ensuring the top of the side pieces and the top board
align, attach the side pieces to the outer can and framing
members.
6. Use a wet or dry towel or a soft brush to remove any
dust or dirt from facing material. Apply a non-combustible
adhesive to attach tile, stone or other non-combustible fin-
ishing materials per manufacturer's instructions.
7. The non-combustible Super Calstick may be used for
sealing between the fireplace and the hearth extension.
Refer to Figure 42.3.
Page 42
Heatilator • Constitution EPA Fireplace • 480-1091C
Metal strips 2 in. (51mm) under edge of
Fireplace and Hearth Extension and 2 in.
(51mm) on both side of fireplace opening.
Nail or screw metal strips in place.
Figure 42.1
Top
Board
Side
Board
Bottom
Board
Side
Board
Figure 42.2
Seal with
non-combustible
sealant
Figure 42.3
Complete installation
Figure 42.4
1in. (25mm) OVERLAP
Tabla superior
Apply bead of
Tabla lateral
Super Calstick to
edge here
Tabla inferior
Tabla lateral
Aplique Super Calstick en el
FIGURA A
FIGURA B Instalación compl
de revestimiento incombustib
#7014-063, 5 de enero de 20