Server Blade Configuration and Utilities
5. Press the Enter key.
6. Press the Esc key to exit the current menu or press the F10 key to exit RBSU.
7. Restart the server blade.
When the server blade boots, the system identifies whether the current ROM bank is
corrupt. If a corrupt ROM is detected, the system boots from the backup ROM and
alerts you through POST or IML that the ROM bank is corrupt.
If both the current and backup versions of the ROM are corrupt, you must return the
system board for a service replacement. Refer to the HP ProLiant BL p-Class System
Maintenance and Service Guide and contact an HP authorized reseller.

Remote ROM Flash

The system contains individual firmware for various components.
The ProLiant BL20p G3 server blade contains:
Server blade system ROM
Smart Array 6i memory module ROM
iLO ROM
The server blade and power enclosures contain:
Server blade management module ROM
Power management module ROM
Using the Smart Components for Remote ROM Flash with the Remote Deployment
Utility (RDU) console application, Remote ROM Flash enables you to upgrade the
firmware (BIOS) on a server blade from a remote location.
If a power loss occurs during a firmware upgrade, redundant ROM support enables
data recovery.