HP ProLiant BL20p Generation 3 User Manual page 16

Hp proliant bl20p generation 3 server blade
Hide thumbs Also See for ProLiant BL20p Generation 3:
Table of Contents

Advertisement

Table 1-2: Hot-Plug SCSI Hard Drive LED Status Combinations
(1) Activity
(2) Online
On
Off
On
Flashing
Flashing
Flashing
Off
Off
Off
Off
HP ProLiant BL20p Generation 3 Server Blade User Guide
(3) Fault
Description
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off
OK to replace the drive online if a predictive failure alert
is received and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, a powered-on controller
is not accessing the drive.
-Or-
The drive is configured as an online spare.
On
OK to replace the drive online.
The drive has failed and has been placed offline.
Server Blade Component Identification
continued
1-5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProLiant BL20p Generation 3 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Proliant bl20p g3

Table of Contents