Connecting to liquefied gas
If you connect the appliance to liquefied gas,
you must always install a suitable gas pressure
regulator.
Use the total gas consumption of the appliance stated
on the rating plate to select a suitable gas pressure
regulator.
Only use connecting lines or flexible hoses which
comply with the applicable regulations and which are
approved for this purpose.
Proceed as follows:
• Screw the corrugated tube union (C) and the seal
(B) to the gas connection (A).
• Hold the corrugated tube union (C) in place with a
spanner and screw the connecting piece to a
flexible gas connecting hose (E).
• Tighten the clamp (D).
E
Only use approved sealing compound to seal the
thread.