Siemens HG193510ME Installation Instructions Manual page 12

Table of Contents

Advertisement

Connecting the mains
cable
Replacing the mains cable
10
Where the appliance is directly connected to the
power supply, an all-pole isolating switch with a
contact gap is required.
Complete disconnection in compliance with the
conditions specified in overvoltage category III must
be guaranteed.
The earth cable is excluded from this.
The mains cable is replaced via the terminal block.
The mains cable must be of the following type:
• H05RRF
• 3 x 0.75 mm²
• 230 V~
Leave the mains cable slightly overlong so that you
can pull out the appliance for cleaning purposes.
Proceed as follows:
• Open the terminal box.
• Undo the screw on the terminal block that fixes
the cable in place.
• Loosen the screw contacts and replace the cable
with a new one of the same length.
The cable must comply with the stipulated specifi-
cations.
• Connect the yellow-green wire to the < terminal.
This wire must be at least 10 mm longer than the
other wires.
• Connect the blue neutral wire to terminal N.
• Connect the brown power wire to
terminal L.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents