Audio - TANDBERG 1000MXP User Manual

Hide thumbs Also See for 1000MXP:
Table of Contents

Advertisement

75Hz
1024x768
48.363kHz
@ 60Hz
Digital
800x600 @
46.875kHz
75Hz
1024x768
48.363kHz
@ 60Hz
DVI-I Video resolution supported in F1 and above
Supported DVI cables:
TANDBERG supports DVI-D Single-Link, DVI-A and DVI-I Single-Link format cables.
DVI-D cables transmit digital T.M.D.S. signals, DVI-A cables transmit analog VGA signals and
DVI-I cables can transmit either digital or analog signals.
It is possible to extend existing DVI cables by the use of extension cables. The maximum cable
length however, is 5 meters. Going beyond that may result in quality loss.
DVI-I - Combined Analog and Digital Connector Pin Assignments:
Pin
Signal
Assignment
1
T.M.D.S.
Data2-
2
T.M.D.S.
Data2+
3
T.M.D.S.
Data2/4 Shield
4
T.M.D.S.
Data4-
5
T.M.D.S.
Data4+
6
DDC Clock
7
DDC Data
8
Analog Vertical
Sync
C1
Analog Red
C4
Analog
Horizontal
Sync
5.1.2

Audio

All audio inputs are active by default. For further information, refer to chapter Audio.
60.004Hz
75.00Hz
60.004Hz
Pin
Signal
Assignment
9
T.M.D.S.
Data1-
10
T.M.D.S.
Data1+
11
T.M.D.S.
Data1/3 Shield
12
T.M.D.S.
Data3-
13
T.M.D.S.
Data3+
14
+5V Power
15
Ground (return
for +5V, HSync
and VSync)
16
Hot Plug Detect
C2
Analog Green
C5
Analog Ground
(analog, R, G &
B return)
Peripheral Equipment
65.00MHz
49.50MHz
65.00MHz
Pin
Signal
Assignment
17
T.M.D.S. Data0-
18
T.M.D.S. Data0+
19
T.M.D.S.
Data0/5 Shield
20
T.M.D.S. Data5-
21
T.M.D.S. Data5+
22
T.M.D.S. Clock
Shield
23
T.M.D.S. Clock+
24
T.M.D.S. Clock-
C3
Analog Blue
175