Platen Open Motor and Belt
1. Unplug the printer power cord from the AC receptacle.
2. Remove the platen belt cover by depressing down to release the top tab,
then tip the cover out while pulling it upward.
3. Remove four 1/4 inch screws and the lower paper guide. (See
Figure 6–7, page 6–40, item #16).
4. If replacing the platen open belt, adjust it (page 5–24), and return the
printer to normal operation.
5. If replacing the platen open motor, remove both the top and bottom
mounting screws, and the power connector (PLM). Replace the motor,
adjust the platen open belt (page 5–24), and return the printer to normal
operation.
Replacement Procedures and Parts
6–29