Hammer Tip Alignment

You must use the alignment tool to correctly align the hammer tips. This
procedure cannot be done accurately by hand.
1. Put the hammer bank in the service position. (See page 5–2.)
2. Loosen the screw (1) of the hammer spring (2) to be aligned.
3. Place the alignment tool (3) (P/N 132266–001) over the hammer tips.
Move the hammer spring until the tip is in an appropriate hole in the
alignment tool.
4. Torque the screw (1) 6 to 9 in–lbs.
5. Remove the alignment tool.
6. Return the hammer bank to the operating position. (See page 5–6.)
5–10
(Figure 5–4)