Display:; Control Specifications; Analog Input; Digital Inputs - Baldor 15P Series Installation And Operating Manual

Inverter control
Hide thumbs Also See for 15P Series:
Table of Contents

Advertisement

Control Specifications:

Control Method
PWM Frequency
V/Hz Ratio
Transistor Type
Torque Boost
Brake Torque
Accel/Decel Time
Base Frequency
Frequency Setting
Accel/Decel
Auto Start
Protective Functions

Analog Input:

Potentiometer Input
Input Full Scale Range
Differential Input Common
Mode Rejection
Input Impedance

Digital Inputs:

(3 Inputs)
Digital Inputs
Input Impedance
Leakage Current
6-2 Specifications and Product Data
Sine wave Carrier input, PWM output
Rated @ 7.5kHz
Linear with adjustable Torque Boost
IGBT (Insulated Gate Bipolar Transistor)
0 to 15% adjustable
Up to 60%, external resistor required
Separate rates, 0.1 to 60 sec.
50 or 60Hz
0-10VDC, 4-20mA, and Rotary on front panel
Separate Accel/Decel rates (0.1 - 60 seconds)
ON or OFF
Inverter trip − Over voltage, over current, under voltage, motor
overload
Short Circuit − Phase to phase and phase to ground
0 - 10VDC
0-10VDC and 4-20mA
40db
20kW
Forward
Reverse
Stop
6.8kW (Closed contacts standard)
10mA Maximum
MN715P

Advertisement

Table of Contents
loading

Table of Contents